Victron Cyrix-i intelligent relay 12/24V-400A – We'd be happy to provide you with more information about this product. Please contact us.
Available for backorder
Victron Cyrix-i intelligent relay 12/24V-400A
Battery voltage monitoring to prevent unwanted switching: Some battery combiners (also called voltage-controlled relays or isolating relays) disconnect a battery in the event of a brief but high current surge. Sometimes a battery combiner will also not connect a large but discharged battery bank because the DC voltage immediately drops below the disconnect value once the batteries are connected. The Cyrix-ct 12/24's software does more than simply connect and disconnect based on battery voltage and a set time delay. The Cyrix-ct 12/24 monitors the overall trend (voltage increase or decrease) and only adjusts the most recently performed action if the trend has changed during a specific time period. The time delay depends on the voltage deviation from the trend. (for battery separators with multiple connection/disconnection profiles, see Cyrix-i 400) Long bolts to allow connection of more than one power cable Cyrix 12/24-120: 13 mm (M6) Cyrix 12/24-230: 16 mm (M8) Protection against overheating (due to prolonged overload e.g.) The Cyrix disengages in the event of excessive contact temperature and re-establishes the connection after it has cooled down again. LED status indication (only with Cyrix 12/24 230) LED on: connected LED on for 10 sec.: disconnected LED on for 2 sec.: connection in progress LED flashing every 2 sec.: connection in progress LED flashing every 0.25 sec.: alarm (overtemperature; voltage > 16V; both batteries < 10V; one battery < 2V) (multiply by 2 for 24V) 12/24 V automatic detection The Cyrix-ct 12/24 automatically detects the system voltage. No voltage loss The Cyrix battery separator is an excellent alternative to diode battery isolators. Its main feature is that there is practically no voltage loss, so the output voltage of alternators or battery chargers does not need to be increased. Starter battery priority It is common practice to connect the alternator directly to the starter battery. The accessory battery, and possibly a bow thruster battery and other batteries, are all connected to the starter battery with a Cyrix battery separator. When the Cyrix detects that the starter battery has reached the coupling voltage, it ensures that all batteries are charged in parallel. Bidirectional voltage measurement and power from both batteries: The Cyrix measures the voltage of both connected batteries. This allows the Cyrix to connect the batteries in parallel even if, for example, the accessory battery is being charged by a battery charger. The Cyrix-ct 12/24 has a dual power supply. This ensures that the Cyrix closes if the voltage of one battery is too low to operate it. To prevent unexpected operation during installation or when one battery is disconnected, the Cyrix-ct 12/24 will not close if the voltage of either battery connection is lower than 2V (for a 12V battery) or 4V (for a 24V battery). Emergency parallel connection (Start Assist) The Cyrix can also be activated via a push button (the Cyrix remains active for 30 seconds) or a switch to manually connect batteries in parallel. This is especially useful in an emergency if the starter battery is flat or defective.
We'd be happy to provide you with more information about this product. Please contact us.
robust-mt.nl