Inverter 12/800 VE.Direct Schuko

Available for backorder

Original price was: €294.03.Current price is: €249.93.

Inverter 12/800 VE.Direct Schuko – We'd be happy to provide you with more information about this product. Please contact us.

SKU: PIN121801200 Categories: , , Brand: Brand:
PIN121801200

Available for backorder

Inverter 12/800 VE.Direct Schuko

Inverter 12/800 VE.Direct Schuko Applications With 650 W continuous and 1500 W peak, even heavier equipment runs on this: microwave, kettle, or a circular saw. Intended for installations where the battery bank can handle it and the 230 V must be reliable, even without shore power or a grid connection. * Campers, vans, and work vans on 12 V * Sloops, motor yachts, and work vessels * Garden sheds, chalets, and off-grid accommodations * Mobile workspaces with power tools * Backup for equipment that must continue operating during a power outage Power and starting behavior * 800 VA nominal; 650 W continuous at 25 °C, 560 W at 40 °C * 1500 W peak power for starting currents of motors, pumps, and power tools * Pure sine wave, suitable for sensitive electronics * Full bridge with toroidal transformer; Short-circuit proof and protected against overheating due to overload or high ambient temperature * Maximum efficiency 90% ECO mode If the load drops below the set threshold, the inverter switches to standby and scans every 2.5 seconds by default to see if there is demand again. The minimum generating power is 15 W by default; both values ​​are adjustable. Consequently, the no-load power drops from 6.5 W to 1 W. The correct setting depends heavily on the type of load: inductive, capacitive, or non-linear. Expect a brief on-site adjustment. Battery monitoring and shutdown * Input voltage range 9.2 – 17 V * Low battery voltage shutdown default 9.3 V, adjustable * Restart and alarm at 10.9 V, battery charged detection at 14.0 V, both adjustable * Dynamic shutdown: the shutdown level follows the load, ensuring the battery bank continues to be utilized under light load * Protected against short circuit, overload, over- and under-battery voltage, over-temperature, and excessive DC ripple voltage, with automatic restart VE.Direct port * Read out and configure via VictronConnect on smartphone or tablet with a VE.Direct Bluetooth Smart dongle * Connection to a PC via a VE.Direct-to-USB interface cable * Adjustable: output voltage 210 – 245 V, frequency 50 or 60 Hz, ECO threshold and search interval, alarm and shutdown levels * Monitoring of battery voltage, AC output voltage, load indication, and alarms Connection and mounting * Schuko socket (CEE 7/4) on the device * DC side on screw terminals, maximum cable cross-section 25 mm²; battery cables are not included * Minimum battery capacity 100 Ah * Recommended DC cable: 16 mm² up to 1.5 m, 25 mm² for 1.5 to 3 m * Internal DC fuse 150 A (BF1 32 V), replaceable; for a DC cable longer than 1.5 m, an additional fuse or DC circuit breaker close to the battery bank is mandatory * Connection for an external on/off switch on the two-pin plug, or between the battery positive terminal and its left contact — useful for switching in conjunction with the ignition switch in a vehicle * Can be mounted vertically or horizontally with four screws, minimum 10 cm clearance all around; IP21 applies only with flush mounting according to the manual; in other positions IP20 * Connecting the battery cables in reverse will cause the internal fuse to blow and may damage the device. Can be ordered directly with this * Victron VE.Direct Bluetooth Smart dongle (https://shop.top.systems/monitoring-controle/draadloos/victron-ve-direct-bluetooth-smart-dongle.html) (ASS030536011) — read out and configure via VictronConnect. Category: Monitoring & control > Wireless (https://shop.top.systems/monitoring-controle/draadloos/) For the DC side, 16 mm² up to 1.5 m or 25 mm² up to 3 m is required, with matching crimp terminals: see Battery cables (https://shop.top.systems/installatie/kabels/accu/) and Crimp terminals (https://shop.top.systems/installatie/accessoires-kabels/perskabelogen/). For cable lengths of 1.5 m or more, an external fuse with holder is required, to be matched to the cable and installation: see Fuses (https://shop.top.systems/beveiligen-schakelen/zekeringen/) and Fuse Holders (https://shop.top.systems/beveiligen-schakelen/zekeringhouders/). Documentation * Manual Inverter VE.Direct 250VA – 1200VA (NL, EN, FR, DE, ES, IT — PDF) (https://www.victronenergy.com/upload/documents/Manual-Inverter-VE.Direct-250VA-1200VA-EN-NL-FR-DE-ES-IT-.pdf) * Datasheet Inverter VE.Direct 250VA – 1600VA (EN, PDF) (https://www.victronenergy.com/upload/documents/Datasheet-Inverter-VE.Direct-250VA-1600VA-EN.pdf) * Dimensions Inverter VE.Direct 12V 800VA (PDF) (https://www.victronenergy.com/upload/documents/Inverter-VE.Direct-12V-800VA.pdf) * Declaration of Conformity Inverter VE.Direct 250VA – 1200VA (PDF) (https://www.victronenergy.com/upload/documents/Inverters-VE.Direct-250VA-1200VA-230V50Hz-and-110V60Hz-2023-10-11.pdf) * Safety Certificate IEC 60335-1 / AS-NZS 4736 – 800VA & 1200VA (PDF) (https://www.victronenergy.com/upload/documents/Certificate-Safety-IEC-60335-1-AS-NZS-4736-Phoenix-Inverter-VE.Direct-800VA-&-1200VA.pdf) * Certificate ECE R10-6 – Inverter VE.Direct 12/800 SCHUKO, IEC, UK (PDF) (https://www.victronenergy.com/upload/documents/Certificate-Automotive-ECE-R10-6-Inverter-VE.Direct-12-800-SCHUKO,-IEC,-UK.pdf) * ECE R10-5 Certificate – Phoenix Inverter VE.Direct 12/800, 24/1200, 48/1200 (PDF) (https://www.victronenergy.com/upload/documents/Certificate-Automotive-ECE-R10-5-Phoenix-Inverter-VE.Direct-12-800,-24-1200,-48-1200.pdf) * ISO 9001 Certificate (PDF) (https://www.victronenergy.com/upload/documents/ISO9001-certificate-2024-EN.pdf) * VE.Direct HEX protocol Phoenix Inverter (EN, PDF) (https://www.victronenergy.com/upload/documents/VE.Direct-HEX-Protocol-Phoenix-Inverter.pdf) Videos * Did You Know – Reduce power consumption of an inverter in standby (EN) (https://www.youtube.com/watch?v=v0s0x0hf66I) Contact At 650 W continuous output from 12 V, more than 60 A easily flows through the battery cables. Battery capacity, cable cross-section, and fuse rating are critical factors here. As an official Victron distributor, we supply from our own stock in Bodegraven and directly from the Victron Energy warehouse, and our engineers calculate the system for you. Contact us (https://www.top.systems/nl/contact/) for advice or a quotation. Specifications System voltage 12 Vdc Nominal power 800 VA Continuous power at 25 °C 650 W Continuous power at 40 °C 560 W Peak power 1500 W Output voltage 230 VAC ±3 %, adjustable 210 – 245 V Frequency 50 or 60 Hz ±0.1 %, adjustable Waveform Pure sine wave Input voltage range 9.2 – 17 V Low battery voltage shutdown 9.3 V, adjustable Restart and low battery voltage alarm 10.9 V, adjustable Battery charged detection 14.0 V, adjustable Dynamic shutdown Load-dependent, configurable Maximum efficiency 90 % No-load power 6.5 W No-load power in ECO mode 1 W ECO mode Yes; Standard wake-up power 15 W, standard search interval 2.5 s, both adjustable Communicative VE.Direct AC output Schuko socket (CEE 7/4), 1 piece AC input No DC connection Screw terminals, maximum 25 mm² Minimum battery capacity 100 Ah Recommended DC cable 16 mm² up to 1.5 m; 25 mm² at 1.5 – 3 m Internal DC fuse 150 A, type BF1 32 V, replaceable Remote on/off Yes, via two-pole plug Automatic changeover switch Filax or Multi Protection class IP21 (IP20 with different mounting position) Operating temperature -40 to +60 °C, fan cooling; above 40 °C 1.25% power degradation per °C Humidity Maximum 95%, non-condensing Dimensions (hxwxd) 105 x 230 x 325 mm Weight 5.5 kg Housing Steel frame with plastic cover Safety standards EN/IEC 60335-1, EN/IEC 62109-1 EMC standards EMCEN 55014-1, EN 55014-2, IEC 61000-6-1, IEC 61000-6-3 Vehicle directive ECE R10-4, EN 50498 Brand Victron Energy Warranty 5 years We would be happy to provide you with more information about this product. Please contact us contact join us.
an electric sloop? See our full range.