EasySolar 12/1600/70-16 MPPT 100/50
EasySolar 12/1600/70-16 MPPT 100/50 Applications Inverter, battery charger, MPPT solar charger, and complete AC distribution in a single cabinet, pre-wired and with battery cables included. This saves half a day of installation and a cabinet full of loose components — ideal for a holiday home or camper that needs to be ready in one go. * Holiday homes, chalets, and garden houses with solar panels * 12V motorhomes and vans with shore power connection * Sloops and smaller vessels with shore power and solar panels * Metering cabinets, site offices, and project locations that need to run on both grid and solar power * Backup systems where the switchover must be seamless What's inside the cabinet * MPPT solar charger 100/50 with three sets of MC4 connectors, allowing for up to three strings of solar panels * Inverter/battery charger MultiPlus Compact 12/1600/70 with 16 A changeover switch * AC distribution with 30 mA / 16 A RCD and four outputs, protected by two 10 A circuit breakers and two 16 A circuit breakers * 1.5-meter battery cables included; solar charger and inverter share the same cables Inverter and PowerAssist * 1600 VA nominal; 1300 W continuous at 25 °C, 1200 W at 40 °C * 3000 W peak power * Output voltage 230 VAC ±2 %, frequency 50 Hz ±0.1 %, both adjustable to 240 V and 60 Hz * PowerAssist: the inverter supplements an insufficient shore or generator connection instead of causing the fuse to blow * Switching during a power outage is so fast that computers and control equipment continue to run * Maximum efficiency 92 % * No-load power 8 W, in search mode 2 W Battery charger * AC input 187 – 265 VAC, 45 – 65 Hz, power factor 1 * Charging current house battery bank 70 A, starter battery 4 A * Absorption 14.4 V, trickle charge 13.8 V, storage mode 13.2 V * Battery temperature sensor included; Adaptive multi-stage charging * Programmable relay, for example for general alarm, DC undervoltage, or starting a generator MPPT solar charger * Model MPPT 100/50: maximum charging current 50 A, maximum PV open-circuit voltage 100 V * Maximum 700 Wp PV power; with more connected power, the controller limits to 700 W * Maximum efficiency 98 %, self-consumption 10 mA * Absorption 14.4 V and trickle charging 13.8 V standard, temperature compensation -16 mV/°C * Adaptive multi-stage charging; the PV voltage must be at least the battery voltage plus 5 V during starting * VE.Direct port on the solar charger Configuration The system can be configured with VEConfigure and the associated Assistants for grid-connected or autonomous operation, including ESS and automatic generator start. Connection to a PC is made via the MK3-USB VE.Bus-to-USB interface; pairing with a GX device provides access to the VRM Portal – Victron Energy (https://www.victronenergy.com/panel-systems-remote-monitoring/vrm). Connection and mounting * Input voltage range 9.5 – 17 V * PV connection via three sets of MC4 connectors * 230 V connection with G-ST18i connector * One 16 A output is driven by the AC input and only switches on when mains voltage or a generator is present * Protected against short circuit, overload, over- and under-battery voltage, over-temperature, 230 VAC on the inverter output, and excessive ripple voltage * Aluminum housing, protection rating IP21; Dry, indoor installation only * Operating temperature -20 to +50 °C with fan cooling Can be ordered directly For configuration via PC, the MK3-USB VE.Bus-to-USB interface is required: see Installation > Interface (https://shop.top.systems/installatie/interface/). For remote monitoring, see Monitoring & control > Control panels (https://shop.top.systems/monitoring-controle/bedieningspanelen/) and Accumonitors (https://shop.top.systems/monitoring-controle/accumonitors/). Solar panels and PV cabling can be found under Solar power > Solar panels (https://shop.top.systems/zonnestroom/zonnepanelen/) and Installation > Cables > Solar (https://shop.top.systems/installatie/kabels/solar/); a DC fuse with holder under Fuses (https://shop.top.systems/beveiligen-schakelen/zekeringen/). Related products * Inverter 12/1600 Compact (https://shop.top.systems/omvormen-laden/omvormen-dc-ac/omvormer-12-1600-compact.html) (CIN122160000) — same inverter base without battery charger, MPPT, and AC distribution Documentation * EasySolar 12V & 24V 1600VA Manual (NL, EN, FR, DE, ES, IT — PDF) (https://www.victronenergy.com/upload/documents/Manual-EasySolar-1600-EN-NL-FR-DE-ES-IT.pdf) * EasySolar 12V & 24V 1600VA Datasheet (EN, PDF) (https://www.victronenergy.com/upload/documents/Datasheet-EasySolar-1600VA-EN.pdf) * EasySolar 12V 1600VA Dimensions 70A MPPT 100/50 (3D, PDF) (https://www.victronenergy.com/upload/documents/EasySolar-12V-1600VA-70AMP-MPPT-100-50.pdf) * EasySolar Declaration of Conformity (PDF) (https://www.victronenergy.com/upload/documents/EasySolar-2021-12-29.pdf) * ISO 9001 Certificate (PDF) (https://www.victronenergy.com/upload/documents/ISO9001-certificate-2024-EN.pdf) * VictronConnect Configuration Guide for VE.Bus Products (EN, HTML5) (https://www.victronenergy.com/media/pg/VictronConnect_configuration_guide_for_VE.Bus_products/en/index-en.html) * VE.Bus Error Codes (EN) (https://www.victronenergy.com/live/ve.bus:ve.bus_error_codes) Contact An all-in-one cabinet saves installation time, but the choice between 12 V and 24 V, the PV power output, and the battery bank determine whether the system performs as your customer expects. As an official Victron distributor, we supply from our own stock in Bodegraven and directly from the Victron Energy warehouse, and our engineers calculate the complete system for you. Contact us (https://www.top.systems/nl/contact/) for advice or a quotation. Specifications System voltage 12 Vdc Inverter nominal power 1600 VA Continuous power at 25 °C 1300 W Continuous power at 40 °C 1200 W Peak power 3000 W Output voltage 230 VAC ±2 %, adjustable to 240 V Frequency 50 Hz ±0.1 %, adjustable to 60 Hz Input voltage range 9.5 – 17 V Maximum inverter efficiency 92 % No-load power 8 W No-load power in search mode 2 W House battery bank charging current 70 A Starter battery charging current 4 A Acceptance charging voltage 14.4 V Trickle charging charging voltage 13.8 V Storage mode 13.2 V AC input 187 – 265 VAC, 45 – 65 Hz, power factor 1 Transmitter 16 A Solar charger MPPT 100/50 Maximum solar charger charging current 50 A Maximum PV power 700 Wp Maximum PV open-circuit voltage 100 V Maximum solar charger efficiency 98 % Solar charger self-consumption 10 mA Temperature compensation -16 mV/°C AC distribution 30 mA / 16 A RCD, four outputs with 2 x 10 A and 2 x 16 A circuit breakers Programmable relay Yes Battery temperature sensor Yes Battery connection 1.5 m battery cables included PV connection Three sets of MC4 connectors AC connection G-ST18i connector Protection class IP21 Operating temperature -20 to +50 °C, fan cooling Humidity Maximum 95 %, non-condensing Dimensions (hxwxd) 745 x 214 x 110 mm Weight 15 kg Housing Aluminum Safety standards EN 60335-1, EN 60335-2-29, EN 62109 EMCEN 55014-1, EN 55014-2, EN 61000-3-3 Brand Victron Energy Warranty 5 years We would be happy to provide you with more information about this product. Please contact us
contact join us.