EasySolar 24/1600/40-16 MPPT 100/50
EasySolar 24/1600/40-16 MPPT 100/50 Applications Inverter, battery charger, MPPT solar charger, and complete AC distribution in a single enclosure, pre-wired and with battery cables included. Moreover, twice as much PV power can be connected at 24 V: up to 1400 Wp, and that at half the DC current. * Holiday homes, chalets, and garden houses with 24 V solar panels * Motorhomes, vans, and service vehicles with shore power connection * Motor yachts and work vessels with shore power and solar panels * Control cabinets, site offices, and project locations that must run on both grid and solar power * Backup systems where the switchover must be seamless What's inside the cabinet * MPPT solar charger 100/50 with three sets of MC4 connectors, allowing for up to three strings of solar panels * Inverter/battery charger MultiPlus Compact 24/1600/40 with 16 A changeover switch * AC distribution with 30 mA / 16 A RCD and four outputs, protected by two 10 A circuit breakers and two 16 A circuit breakers * 1.5-meter battery cables included; solar charger and inverter share the same cables Inverter and PowerAssist * 1600 VA nominal; 1300 W continuous at 25 °C, 1200 W at 40 °C * 3000 W peak power * Output voltage 230 VAC ±2 %, frequency 50 Hz ±0.1 %, both adjustable to 240 V and 60 Hz * PowerAssist: the inverter supplements an insufficient shore or generator connection instead of causing the fuse to blow * Switching during a power outage is so fast that computers and control equipment continue to run * Maximum efficiency 94 % * No-load power 10 W, in search mode 3 W Battery charger * AC input 187 – 265 VAC, 45 – 65 Hz, power factor 1 * Charging current house battery bank 40 A, starter battery 4 A * Absorption 28.8 V, trickle charge 27.6 V, storage mode 26.4 V * Battery temperature sensor included; Adaptive multi-stage charging * Programmable relay, for example for general alarm, DC undervoltage, or starting a generator MPPT solar charger * Model MPPT 100/50: maximum charging current 50 A, maximum PV open-circuit voltage 100 V * Maximum 1400 Wp PV power; with more connected power, the controller limits to 1400 W * Maximum efficiency 98%, self-consumption 10 mA * Absorption 28.8 V and trickle charging 27.6 V standard, temperature compensation -32 mV/°C * Adaptive multi-stage charging; the PV voltage must be at least the battery voltage plus 5 V during starting * VE.Direct port on the solar charger Configuration The system can be configured for grid-connected or autonomous operation using VEConfigure and the associated Assistants, including ESS and automatic generator start. Connection to a PC is made via the MK3-USB VE.Bus-to-USB interface; connection to a GX device provides access to the VRM Portal – Victron Energy (https://www.victronenergy.com/panel-systems-remote-monitoring/vrm). Connection and mounting * Input voltage range 19 – 33 V * PV connection on three sets of MC4 connectors * 230 V connection with G-ST18i connector * One 16 A output is driven by the AC input and only switches on when mains voltage or a generator is present * Protected against short circuit, overload, over- and under-battery voltage, over-temperature, 230 VAC on the inverter output, and excessive ripple voltage * Aluminum housing, protection rating IP21; Dry, indoor installation only * Operating temperature -20 to +50 °C with fan cooling Can be ordered directly For configuration via PC, the MK3-USB VE.Bus-to-USB interface is required: see Installation > Interface (https://shop.top.systems/installatie/interface/). For remote monitoring, see Monitoring & control > Control panels (https://shop.top.systems/monitoring-controle/bedieningspanelen/) and Accumonitors (https://shop.top.systems/monitoring-controle/accumonitors/). Solar panels and PV cabling can be found under Solar power > Solar panels (https://shop.top.systems/zonnestroom/zonnepanelen/) and Installation > Cables > Solar (https://shop.top.systems/installatie/kabels/solar/); a DC fuse with holder under Fuses (https://shop.top.systems/beveiligen-schakelen/zekeringen/). Related products * Inverter 24/1600 Compact (https://shop.top.systems/omvormen-laden/omvormen-dc-ac/omvormer-24-1600-compact.html) — same inverter base without battery charger, MPPT and AC distribution Documentation * EasySolar 12V & 24V 1600VA Manual (NL, EN, FR, DE, ES, IT — PDF) (https://www.victronenergy.com/upload/documents/Manual-EasySolar-1600-EN-NL-FR-DE-ES-IT.pdf) * EasySolar 12V & 24V 1600VA Datasheet (EN, PDF) (https://www.victronenergy.com/upload/documents/Datasheet-EasySolar-1600VA-EN.pdf) * EasySolar Declaration of Conformity (PDF) (https://www.victronenergy.com/upload/documents/EasySolar-2021-12-29.pdf) * ISO 9001 certificate (PDF) (https://www.victronenergy.com/upload/documents/ISO9001-certificate-2024-EN.pdf) * VictronConnect configuration guide for VE.Bus products (EN, HTML5) (https://www.victronenergy.com/media/pg/VictronConnect_configuration_guide_for_VE.Bus_products/en/index-en.html) * VE.Bus error codes (EN) (https://www.victronenergy.com/live/ve.bus:ve.bus_error_codes) Contact At 24 V, twice as much PV can be installed on this unit than on the 12 V version, and that makes all the difference once solar yield becomes the primary factor. As an official Victron distributor, we supply from our own stock in Bodegraven and directly from the Victron Energy warehouse, and our engineers calculate the complete system for you. Contact us (https://www.top.systems/nl/contact/) for advice or a quotation. Specifications System voltage 24 Vdc Inverter nominal power 1600 VA Continuous power at 25 °C 1300 W Continuous power at 40 °C 1200 W Peak power 3000 W Output voltage 230 VAC ±2 %, adjustable to 240 V Frequency 50 Hz ±0.1 %, adjustable to 60 Hz Input voltage range 19 – 33 V Maximum inverter efficiency 94 % No-load power 10 W No-load power in search mode 3 W House battery bank charging current 40 A Starter battery charging current 4 A Absorption charging voltage 28.8 V Trickle charging charging voltage 27.6 V Storage mode 26.4 V AC input 187 – 265 VAC, 45 – 65 Hz, power factor 1 Transmitter 16 A Solar charger MPPT 100/50 Maximum solar charger charging current 50 A Maximum PV power 1400 Wp Maximum PV open-circuit voltage 100 V Maximum solar charger efficiency 98 % Solar charger self-consumption 10 mA Temperature compensation -32 mV/°C AC distribution 30 mA / 16 A RCD, four outputs with 2 x 10 A and 2 x 16 A circuit breakers Programmable relay Yes Battery temperature sensor Yes Battery connection 1.5 m battery cables included PV connection Three sets of MC4 connectors AC connection G-ST18i connector Protection class IP21 Operating temperature -20 to +50 °C, fan cooling Humidity Maximum 95 %, non-condensing Dimensions (hxwxd) 745 x 214 x 110 mm Weight 15 kg Housing Aluminum Safety standards EN 60335-1, EN 60335-2-29, EN 62109 EMCEN 55014-1, EN 55014-2, EN 61000-3-3 Brand Victron Energy Warranty 5 years We would be happy to provide you with more information about this product. Please contact us
contact join us.