Inverter 24/500 VE.Direct Schuko

Available for backorder

Original price was: €200.86.Current price is: €170.73.

Inverter 24/500 VE.Direct Schuko – We'd be happy to provide you with more information about this product. Please contact us.

PIN241501200

Available for backorder

Inverter 24/500 VE.Direct Schuko

24/500 VE Converter.Direct Schuko Applications Enough power for a refrigerator plus some small items, and still compact. At 24 V, the DC current remains low, allowing for thinner cables and a smaller fuse. With ECO mode, the standby power consumption drops to around 1.5 watts. * 24 V commercial vehicles, trucks, and service vehicles * Sloops, motor yachts, and work vessels on 24 V * Garden sheds, chalets, and off-grid accommodations * Metering cabinets, telecom locations, and pump installations in rural areas * Backup for equipment that must continue operating during a power outage Power and starting behavior * 500 VA nominal; 400 W continuous at 25 °C, 350 W at 40 °C * 900 W peak power for starting currents of LED drivers, incandescent lamps, and power tools * Pure sine wave, suitable for sensitive electronics * Full bridge with toroidal transformer; Short-circuit proof and protected against overheating due to overload or high ambient temperature * Maximum efficiency 90% ECO mode If the load drops below the set threshold, the inverter switches to standby and scans every 2.5 seconds by default to see if there is demand again. The minimum generating power is 15 W by default; both values ​​are adjustable. Consequently, the no-load power drops from 6.5 W to 1.5 W. The correct setting depends heavily on the type of load: inductive, capacitive, or non-linear. Expect a brief on-site adjustment. Battery monitoring and shutdown * Input voltage range 18.4 – 34.0 V * Low battery voltage shutdown default 18.6 V, adjustable * Restart and alarm at 21.8 V, battery charged detection at 28.0 V, both adjustable * Dynamic shutdown: the shutdown level follows the load, ensuring the battery bank continues to be utilized under light load * Protected against short circuit, overload, over- and under-battery voltage, over-temperature, and excessive DC ripple voltage, with automatic restart VE.Direct port * Read out and configure via VictronConnect on smartphone or tablet with a VE.Direct Bluetooth Smart dongle * Connection to a PC via a VE.Direct-to-USB interface cable * Adjustable: output voltage 210 – 245 V, frequency 50 or 60 Hz, ECO threshold and search interval, alarm and shutdown levels * Monitoring of battery voltage, AC output voltage, load indication, and alarms Connection and mounting * Schuko socket (CEE 7/4) on the device * DC side on screw terminals, maximum cable cross-section 10 mm²; battery cables are not included * Minimum battery capacity 40 Ah * Recommended DC cable: 6 mm² up to 1.5 m, 10 mm² for 1.5 to 3 m * Internal DC fuse 2 x 25 A (ATOF 32 V), non-replaceable; for a DC cable longer than 1.5 m, an additional fuse or DC circuit breaker close to the battery bank is mandatory * Connection for an external on/off switch on the two-pole plug, or between the battery positive terminal and its left contact * Can be mounted vertically or horizontally with four screws, minimum 10 cm clearance all around; IP21 applies only with flush mounting according to the manual; in other positions IP20 * Connecting the battery cables in reverse will cause the internal fuse to blow and may damage the device. Can be ordered directly with this * Victron VE.Direct Bluetooth Smart dongle (https://shop.top.systems/monitoring-controle/draadloos/victron-ve-direct-bluetooth-smart-dongle.html) (ASS030536011) — read out and configure via VictronConnect. Category: Monitoring & control > Wireless (https://shop.top.systems/monitoring-controle/draadloos/) * Red battery cable 6mm² per meter (https://shop.top.systems/assortiment/details/?webgroupfilter=14&artdetail=KABRD0100600) (KABRD0100600). Category: Installation > Cables > Battery (https://shop.top.systems/installatie/kabels/accu/) * Battery cable black 6mm² per meter (https://shop.top.systems/assortiment/details/?webgroupfilter=14&artdetail=KABZW0100600) (KABZW0100600). Category: Installation > Cables > Battery (https://shop.top.systems/installatie/kabels/accu/) * Battery cable red 6mm² 150 cm 1 x M8 (https://shop.top.systems/assortiment/details/?webgroupfilter=14&artdetail=KABRD061508M) (KABRD061508M). Category: Installation > Cables > Battery (https://shop.top.systems/installatie/kabels/accu/) * Battery cable black 6mm² 150 cm 1 x M8 (https://shop.top.systems/assortiment/details/?webgroupfilter=14&artdetail=KABZW061508M) (KABZW061508M). Category: Installation > Cables > Battery (https://shop.top.systems/installatie/kabels/accu/) * Crimp cable lug 6mm² > M6 (https://shop.top.systems/assortiment/details/?webgroupfilter=14&artdetail=PSKABOG00006) (PSKABOG00006). Category: Installation > Cable accessories > Crimp lugs (https://shop.top.systems/installatie/accessoires-kabels/perskabelogen/) * Crimp lug 6mm² > M8 (https://shop.top.systems/assortiment/details/?webgroupfilter=14&artdetail=PSKABOG00007) (PSKABOG00007). Category: Installation > Cable accessories > Crimp lugs (https://shop.top.systems/installatie/accessoires-kabels/perskabelogen/) For a cable length between 1.5 and 3 m, 10 mm² is required; you can find this in the Battery cables category (https://shop.top.systems/installatie/kabels/accu/). From 1.5 m upwards, an external fuse with holder is also required: see Fuses (https://shop.top.systems/beveiligen-schakelen/zekeringen/) and Fuse holders (https://shop.top.systems/beveiligen-schakelen/zekeringhouders/). Related products * Inverter 24/250 VE.Direct Schuko (https://shop.top.systems/omvormen-laden/omvormen-dc-ac/omvormer-24-250-ve-direct-schuko.html) (PIN241251200) — 200 W continuous and 400 W peak * Inverter 24/800 VE.Direct Schuko (https://shop.top.systems/omvormen-laden/omvormen-dc-ac/omvormer-24-800-ve-direct-schuko.html) (PIN241801200) — 650 W continuous and 1500 W peak Documentation * Manual Inverter VE.Direct 250VA – 1200VA (NL, EN, FR, DE, ES, IT — PDF) (https://www.victronenergy.com/upload/documents/Manual-Inverter-VE.Direct-250VA-1200VA-EN-NL-FR-DE-ES-IT-.pdf) * Datasheet Inverter VE.Direct 250VA – 1600VA (EN, PDF) (https://www.victronenergy.com/upload/documents/Datasheet-Inverter-VE.Direct-250VA-1600VA-EN.pdf) * Dimensions Inverter VE.Direct 12V/24V/48V 500VA (PDF) (https://www.victronenergy.com/upload/documents/Inverter-VE.Direct-12V-24V-48V-500VA.pdf) * Declaration of Conformity Inverter VE.Direct 250VA – 1200VA (PDF) (https://www.victronenergy.com/upload/documents/Inverters-VE.Direct-250VA-1200VA-230V50Hz-and-110V60Hz-2023-10-11.pdf) * Safety Certificate IEC 60335-1 / AS-NZS 4736 – 250VA, 375VA, 500VA (PDF) (https://www.victronenergy.com/upload/documents/Certificate-Safety-IEC-60335-1-AS-NZS-4736-Phoenix-Inverter-VE.Direct-250-375-500VA.pdf) * Certificate ECE R10-6 – Inverter VE.Direct 250VA, 375VA, 500VA (PDF) (https://www.victronenergy.com/upload/documents/Certificate-Automotive-ECE-R10-6-Inverter-VE.Direct-250VA,-375VA,-500VA.pdf) * ECE R10-5 Certificate – Phoenix Inverters 250VA, 375VA, 500VA (PDF) (https://www.victronenergy.com/upload/documents/Certificate-Automotive-ECE-R10-4-–-Phoenix-Inverters-250VA,-375VA,-500VA.pdf) * ISO 9001 Certificate (PDF) (https://www.victronenergy.com/upload/documents/ISO9001-certificate-2024-EN.pdf) * VE.Direct HEX Protocol Phoenix Inverter (EN, PDF) (https://www.victronenergy.com/upload/documents/VE.Direct-HEX-Protocol-Phoenix-Inverter.pdf) Videos * Did You Know – Reduce power consumption of an inverter in standby (EN) (https://www.youtube.com/watch?v=v0s0x0hf66I) Contact Battery capacity, cable length, and ECO setting determine whether this device performs as your customer expects in practice. As an official Victron distributor, we supply from our own stock in Bodegraven and directly from the Victron Energy warehouse, and our engineers will calculate it with you in a few minutes. Contact us (https://www.top.systems/nl/contact/) for advice or a quote. Specifications System voltage 24 Vdc Nominal power 500 VA Continuous power at 25 °C 400 W Continuous power at 40 °C 350 W Peak power 900 W Output voltage 230 VAC ±3 %, adjustable 210 – 245 V Frequency 50 or 60 Hz ±0.1 %, adjustable Waveform Pure sine wave Input voltage range 18.4 – 34.0 V Low battery voltage shutdown 18.6 V, adjustable Restart and low battery voltage alarm 21.8 V, adjustable Battery charged detection 28.0 V, adjustable Dynamic shutdown Load-dependent, configurable Maximum efficiency 90 % No-load power 6.5 W No-load power in ECO mode 1.5 W ECO mode Yes; Standard wake-up power 15 W, standard search interval 2.5 s, both adjustable Communicative VE.Direct AC output Schuko socket (CEE 7/4), 1 piece AC input No DC connection Screw terminals, maximum 10 mm² Minimum battery capacity 40 Ah Recommended DC cable 6 mm² up to 1.5 m; 10 mm² at 1.5 – 3 m Internal DC fuse 2 x 25 A, type ATOF 32 V, non-replaceable Remote on/off Yes, via two-pole plug Automatic changeover switch Filax or Multi Protection class IP21 (IP20 with different mounting position) Operating temperature -40 to +60 °C, fan cooling; above 40 °C 1.25% power degradation per °C Humidity Maximum 95%, non-condensing Dimensions (hxwxd) 86 x 172 x 275 mm Weight 3.9 kg Housing Steel frame with plastic cover Safety standards EN/IEC 60335-1, EN/IEC 62109-1 EMC standards EMCEN 55014-1, EN 55014-2, IEC 61000-6-1, IEC 61000-6-3 Vehicle directive ECE R10-4, EN 50498 Brand Victron Energy Warranty 5 years We would be happy to provide you with more information about this product. Please contact us contact join us.
an electric sloop? See our full range.