MultiPlus-II 48/4k5/55-32 230V

Available for backorder

Original price was: €930.49.Current price is: €790.92.

MultiPlus-II 48/4k5/55-32 230V – We would be happy to provide you with more information about this product. Please contact us.

PMP482405012

Available for backorder

MultiPlus-II 48/4k5/55-32 230V

MultiPlus-II 48/4k5/55-32 230V Applications For home batteries, commercial buildings, and off-grid installations on a 32A connection. Four kW continuous, 6 kW momentary, and a transfer within 20 ms keep critical groups operational, even when the grid fails or the generator still needs to start. Inverter and battery charger in one housing A 4 kW continuous pure sine wave inverter, a 55 A adaptive battery charger, and a 32 A transfer switch. The model features built-in island protection and an external current sensor option that allows PowerControl and PowerAssist to extend beyond the input current. Power with time window * 4 kW continuous at 25 °C, 3.7 kW at 40 °C, and 3 kW at 65 °C. * Time-limited 4.5 kW for 2 hours and 6 kW for 25 minutes (cold start). * Peak power 7 kW for 1 minute, for loads with a high inrush current. Two AC outputs * AC-out-1 is uninterruptible: in the event of a power outage, the inverter takes over the load within 20 ms, ensuring that computers and other electronics continue to run. * AC-out-2 (32 A) is only active as long as AC voltage is present at the input. Suitable for a water heater or air conditioning unit that must not discharge the battery bank. PowerControl and PowerAssist A maximum mains or generator current can be set; the MultiPlus-II charges only with the remaining current, thus preventing overloading of the connection. PowerAssist supplements short-term peaks from the battery bank and recharges as the load decreases. With the optional external AC current sensor (up to 100 A), self-consumption can be further optimized and feed-in limited. ESS and Solar Energy The model is the core component of a Victron ESS installation and works in conjunction with MPPT charge controllers and grid-connected PV inverters, both off-grid and grid-connected. Self-consumption, backup, and charging during low electricity prices can be combined; the maximum apparent feed-in power is 4 kW. Battery Charger * Maximum charging current 55 A at 25 °C and 50 A at 40 °C. * Absorption 57.6 V, trickle charging 55.2 V, storage mode 52.8 V. * AC input range 187-265 VAC, 45-65 Hz. * The battery temperature sensor is optional and can be ordered separately. Parallel and Three-Phase Up to 6 units can be connected in parallel for higher output power and higher charging current. Three units of the same type form a three-phase system; multiple sets of three can be connected in parallel per phase. A split-phase installation is possible with a separate autotransformer. Configuration and remote reading * Setup using VEConfigure or VictronConnect via an MK3 USB interface. * Local reading using a communication center such as the Cerbo GX or Ekrano GX, a battery monitor, a control panel, or via Bluetooth with a VE.Bus Smart dongle. * Remote reading and configuration via the VRM Portal – Victron Energy (https://vrm.victronenergy.com/landingpage). * Two general-purpose ports for, among other things, communication with the battery management system of a lithium battery bank, plus a programmable relay and remote on/off. Documentation * Datasheet MultiPlus-II new models 4k 4k5 6k5 (EN) (https://www.victronenergy.com/upload/documents/Datasheet-MultiPlus-II-inverter-charger-4k-4k5-6k5-EN-.pdf) * Manual MultiPlus-II 4k 4k5 6k5 230V (EN) (https://www.victronenergy.com/upload/documents/MultiPlus-II_4k_4k5_6k5_230V/32424-MultiPlus-II___Quattro-II-pdf-en.pdf) * Victron Energy ISO 9001 certificate (https://www.victronenergy.com/upload/documents/ISO9001-certificate-2024-EN.pdf) Contact Are you unsure about the battery capacity, fuse size, or grid code certification for your project? Our specialists will calculate the installation with you and supply from stock. Contact Top Systems (https://www.top.systems/nl/contact/). Specifications Nominal battery voltage 48 V DC input voltage range 38 – 60 V Continuous output power at 25 °C 4 kW Continuous output power at 40 °C 3.7 kW Continuous output power at 65 °C 3 kW Time-limited power (cold start) 4.5 kW / 2 hours and 6 kW / 25 min Peak power 7 kW for 1 min Output voltage 230 VAC ± 2 %, 50 Hz ± 0.1 % (adjustable to 60 Hz) Maximum charging current at 25 °C / 40 °C 55 A / 50 A Charging voltage absorption / float / storage 57.6 / 55.2 / 52.8 V Maximum switching current / AC input current 32 A AC input range 187 – 265 VAC, 45 – 65 Hz Number of AC outputs 2 Auxiliary output AC-out-232 A Max. Apparent feed-in capacity 4 kW Maximum efficiency 95 % No-load power 20 W No-load power AES mode 13 W External AC current sensor Optional, 100 A Communicative VE.Bus, 2x general purpose port, remote on/off Programmable relay Yes Warranty 5 years We would be happy to provide you with more information about this product. Please contact us contact join us.
an electric sloop? See our full range.