MultiPlus-II 48/5000/70-50 230V
MultiPlus-II 48/5000/70-50 230V Applications The basis of virtually every 48 V energy storage system: home batteries, commercial buildings, emergency power, and self-sufficient installations. Also suitable for maritime and mobile applications with heavy loads and limited shore or generator power. PowerControl and PowerAssist Set the maximum grid, shore, or generator current; charging only takes place using the remaining current, so that the source does not become overloaded. During short-term peaks, the battery bank immediately replenishes the deficit, and the reserve capacity is then used again for charging. With the optional external AC current sensor, the measuring range can be extended to 100 A. ESS and solar energy Core component of a Victron ESS installation, with built-in islanding protection. Can be combined with MPPT solar chargers and grid-connected PV inverters for self-consumption, backup, and charging during low electricity prices. Maximum apparent power 5000 VA. Two AC outputs. The main output operates uninterrupted and takes over within 20 milliseconds in the event of a mains failure or loss of shore or generator power. The 50 A auxiliary output is only energized as long as AC voltage is present at the input; intended for loads that must not discharge the battery bank, such as a water heater. Battery charger. Adaptive charging with absorption 57.6 V, trickle charging 55.2 V, and storage mode 52.8 V, with a charging current of up to 70 A. The charging algorithm can be adapted using VEConfigure for lead-acid, AGM, gel, and lithium, among others. The battery temperature sensor is not included with the 48 V version; it can be ordered separately under ASS000001000. Parallel and 3-phase operation. Up to six units in parallel: six 48/5000/70 units together deliver 25 kW / 30 kVA with a 420 A charging capacity. Three units of the same model form a 3-phase system, and up to six such sets can be connected in parallel, providing 75 kW / 90 kVA and a load capacity of over 1200 A. Low self-consumption. No-load power 18 W, 12 W in AES mode, and 2 W in search mode. Programmable relay. Configurable for general alarm, DC undervoltage, or aggregate start/stop. Load capacity 230 V / 4 A AC, 4 A up to 35 V DC, and 1 A up to 60 V DC. Configuration, monitoring, and control. Setup using VEConfigure via the MK3 USB interface or the VictronConnect app. Available options for monitoring and control include a Cerbo GX or Ekrano GX communication center, a Digital Multi Control panel, a battery monitor, and the VE.Bus Smart dongle. The system can be monitored and adjusted remotely in the VRM Portal – Victron Energy (https://vrm.victronenergy.com) via a GX device with an internet connection. Available to order directly * Red battery cable 70mm² per meter, KABRD0107000 – go to the item (https://shop.top.systems/default.asp?pageid=88&webgroupfilter=16&artdetail=KABRD0107000) | category Battery cables (https://shop.top.systems/installatie/kabels/accu/) * Black battery cable 70mm² per meter, KABZW0107000 – go to the item (https://shop.top.systems/default.asp?pageid=88&webgroupfilter=16&artdetail=KABZW0107000) | category Battery cables (https://shop.top.systems/installatie/kabels/accu/) * Battery cable adapter red 70mm² 150cm M8-M8, KABRD70150M8 – to the item (https://shop.top.systems/default.asp?pageid=88&webgroupfilter=16&artdetail=KABRD70150M8) | category Battery cables (https://shop.top.systems/installatie/kabels/accu/) * Battery cable adapter black 70mm² 150cm M8-M8, KABZW70150M8 – to the item (https://shop.top.systems/default.asp?pageid=88&webgroupfilter=16&artdetail=KABZW70150M8) | category Battery cables (https://shop.top.systems/installatie/kabels/accu/) * Crimp cable lug 70mm² > M8, PSKABOG00071 – to the item (https://shop.top.systems/default.asp?pageid=88&webgroupfilter=16&artdetail=PSKABOG00071) | category Crimp cable lugs (https://shop.top.systems/installatie/accessoires-kabels/perskabelogen/) * Crimp cable lug 70mm² > M10, PSKABOG00072 – to the item (https://shop.top.systems/default.asp?pageid=88&webgroupfilter=16&artdetail=PSKABOG00072) | category Crimp cable lugs (https://shop.top.systems/installatie/accessoires-kabels/perskabelogen/) * Insulation cap 35/50/70mm² double red, ISKP600N4 – to the item (https://shop.top.systems/default.asp?pageid=88&webgroupfilter=16&artdetail=ISKP600N4) | category Insulation caps (https://shop.top.systems/installatie/accessoires-kabels/isolatiekappen/) * Insulation cap 35/50/70mm² double black, ISKP600N41 – to the item (https://shop.top.systems/default.asp?pageid=88&webgroupfilter=16&artdetail=ISKP600N41) | category Insulation caps (https://shop.top.systems/installatie/accessoires-kabels/isolatiekappen/) * Red heat shrink tubing 50cm for 35/50/70mm battery cable, KRKR01191955 – to the item (https://shop.top.systems/default.asp?pageid=88&webgroupfilter=16&artdetail=KRKR01191955) | category Heat shrink tubing (https://shop.top.systems/installatie/accessoires-kabels/krimpkousen/) * Black heat shrink tubing 50cm for 35/50/70mm battery cable, KRKZ01191955 – to the item (https://shop.top.systems/default.asp?pageid=88&webgroupfilter=16&artdetail=KRKZ01191955) | category Heat shrink tubing (https://shop.top.systems/installatie/accessoires-kabels/krimpkousen/) * LittelFuse fuse 200A MEGA 70V-SF51, ZEKLFM070200 – to the item (https://shop.top.systems/default.asp?pageid=88&webgroupfilter=16&artdetail=ZEKLFM070200) | category Fuses (https://shop.top.systems/beveiligen-schakelen/zekeringen/) * Mega fuse holder M8 35-300A, ZEKHD0000800 – to the item (https://shop.top.systems/default.asp?pageid=88&webgroupfilter=16&artdetail=ZEKHD0000800) | category Fuse holders (https://shop.top.systems/beveiligen-schakelen/zekeringhouders/) * Victron SmartShunt 500A/50mV, SHU050150050 – to the article (https://shop.top.systems/default.asp?pageid=88&webgroupfilter=16&artdetail=SHU050150050) | category Battery monitors (https://shop.top.systems/monitoring-controle/accumonitors/) * Victron SmartShunt 500A/50mV IP65, SHU065150050 – to the article (https://shop.top.systems/default.asp?pageid=88&webgroupfilter=16&artdetail=SHU065150050) | category Battery monitors (https://shop.top.systems/monitoring-controle/accumonitors/) * Victron Cerbo GX MK2, BPP900450110 – to the article (https://shop.top.systems/default.asp?pageid=88&webgroupfilter=16&artdetail=BPP900450110) * Cerbo GX Touch 50, BPP900455050 – to the article (https://shop.top.systems/default.asp?pageid=88&webgroupfilter=16&artdetail=BPP900455050) Related products * MultiPlus-II 48/5000/70-50, PMP482505010 – to the article (https://shop.top.systems/default.asp?pageid=88&webgroupfilter=16&artdetail=PMP482505010) Documentation * Datasheet MultiPlus-II Inverter/Charger 230 V (EN) (https://www.victronenergy.com/upload/documents/Datasheet-MultiPlus-II-inverter-charger-EN-.pdf) * Manual MultiPlus-II 230V (NL) (https://www.victronenergy.com/upload/documents/MultiPlus-II_230V/32424-MultiPlus-II___Quattro-II-pdf-nl.pdf) * ISO 9001 certificate (NL) (https://www.victronenergy.com/upload/documents/ISO9001-certificate-2024-NL.pdf) Contact Do you want to be sure that the cable cross-section, fuse, and battery bank match? Our product specialists calculate your installation and help you with the ESS configuration. Contact us (https://www.top.systems/nl/contact/). Specifications Nominal battery voltage 48 V Continuous output power at 25 °C 5000 VA / 4000 W Continuous output power at 40 °C 3700 W Continuous output power at 65 °C 3000 W Peak power 9000 W Maximum battery charging current 70 A Automatic transfer switch 50 A Maximum AC input current 50 A Number of AC outputs 2 Auxiliary output Yes, 50 A Maximum apparent reverse power 5000 VA Input voltage range DC 38 – 66 V Output voltage 230 V AC ± 2 %, 50 Hz ± 0.1 % AC input voltage range 187 – 265 V AC, 45 – 65 Hz Charging voltage absorption / trickle / storage 57.6 / 55.2 / 52.8 V Maximum efficiency 96 % No-load power 18 W No-load power AES mode 12 W No-load power search mode 2 W Battery temperature sensor Optional, ASS000001000 External AC current sensor Optional, 100 A Programmable relay Yes, 230 V / 4 A AC; 4 A up to 35 V DC, 1 A up to 60 V DC Communication VE.Bus, 2x general communication ports, remote on/off Operating temperature -40 to +65 °C, fan-assisted cooling Maximum humidity 95 %, non-condensing Maximum altitude 2000 m Housing material Steel Protection class IP22 Battery connection Four M8 bolts, 2 plus and 2 minus 230 V AC connection Screw terminals 13 mm² Dimensions (hxwxd) 565 x 320 x 149 mm Weight 30 kg Safety standards EN-IEC 60335-1, EN-IEC 60335-2-29, EN-IEC 62109-1, EN-IEC 62109-2 EAN 8719076058366 We would be happy to provide you with more information about this product. Please contact us
contact join us.