MultiPlus-II 48/6k5/100-50 230V GX
MultiPlus-II 48/6k5/100-50 230V GX Applications The basis of virtually every 48V energy storage system: home batteries, commercial buildings, emergency power, and self-sufficient installations. Also suitable for maritime and mobile applications with heavy loads and limited shore or generator power. Built-in GX communication center The inverter/battery charger and GX device are housed in a single enclosure, featuring a 2 x 16-character display showing battery, inverter, and PV charge controller parameters. The same data can be accessed via Wi-Fi using a smartphone, tablet, or laptop. This eliminates the need for a separate GX device, cabling, and installation time. Interfaces The GX section features a BMS-CAN interface for a compatible CAN-bus managed battery, a VE.Direct port, a USB port, an Ethernet port, and Wi-Fi. Note: the BMS-CAN port is not a VE.CAN port. PowerControl and PowerAssist Set the maximum grid, shore, or generator current; the remaining capacity goes to the battery charger so that the source does not become overloaded. During peak load, the battery bank immediately replenishes the deficit, and the reserve capacity is then used again for charging. With the optional external AC current sensor, this range extends up to 100 A. ESS and Feed-in Core component of a Victron ESS installation, to be combined with MPPT solar chargers and grid-connected PV inverters. Using data from an external current sensor or energy meter, self-consumption is optimized and feed-in can be limited or blocked. Maximum apparent feed-in power 6 kW. Power and time-limited power 6 kW continuous at 25 °C, 5.7 kW at 40 °C, and 4.6 kW at 65 °C. After a cold start, 6.5 kW is available for 4 hours and 8 kW for 1 hour. The peak power is 11 kW for 1 minute. Two AC outputs. The main output operates uninterrupted and takes over within 20 milliseconds in the event of a mains failure or loss of shore or generator power. The 32 A auxiliary output is only energized as long as AC is present at the input and is intended for loads that must not discharge the battery bank. Battery charger. Adaptive charging with absorption 57.6 V, trickle charging 55.2 V, and storage mode 52.8 V. Charging current 100 A at 25 °C and 95 A at 40 °C. Suitable for LiFePO4, lead-acid, and zinc-bromine, among others, provided the charger is configured according to the battery manufacturer's specifications. The battery temperature sensor is optional, item number ASS000001000. Parallel and 3-phase operation. Up to six identical units in parallel and 3-phase operation in a star configuration via standard RJ45 UTP cables. Since only one GX device is permitted per system, coupled units must be of the same model. For larger systems, a version without a built-in GX device using an external GX device may be more practical. The product is not suitable for a 3-phase delta configuration. Low self-consumption. No-load power 28 W, 18 W in AES mode, and 8 W in search mode. Programmable relay. Can be configured for general alarm, DC undervoltage, or generator start/stop. Load capacity 230 V / 4 A AC, 4 A up to 35 V DC, and 1 A up to 60 V DC. Remote monitoring and control. Via the Ethernet or Wi-Fi connection, the system can be monitored and adjusted locally and remotely in the VRM Portal – Victron Energy (https://vrm.victronenergy.com), including alarm notifications via email or push message. Settings are changed using VEConfigure or the VictronConnect app. Can be ordered directly with this * Cable set 35mm² 1.5 m red and black M8-M8, KABSET010351 – go to the item (https://shop.top.systems/default.asp?pageid=88&webgroupfilter=16&artdetail=KABSET010351) | category Battery cables (https://shop.top.systems/installatie/kabels/accu/) * Battery cable red 35mm² per meter, KABRD0103500 – go to the item (https://shop.top.systems/default.asp?pageid=88&webgroupfilter=16&artdetail=KABRD0103500) | category Battery cables (https://shop.top.systems/installatie/kabels/accu/) * Battery cable black 35mm² per meter, KABZW0103500 – to the item (https://shop.top.systems/default.asp?pageid=88&webgroupfilter=16&artdetail=KABZW0103500) | category Battery cables (https://shop.top.systems/installatie/kabels/accu/) * Crimp cable lug 35mm² > M8, PSKABOG00036 – to the item (https://shop.top.systems/default.asp?pageid=88&webgroupfilter=16&artdetail=PSKABOG00036) | category Crimp cable lugs (https://shop.top.systems/installatie/accessoires-kabels/perskabelogen/) * Crimp cable lug 70mm² > M8, PSKABOG00071 – to the item (https://shop.top.systems/default.asp?pageid=88&webgroupfilter=16&artdetail=PSKABOG00071) | category Crimp cable lugs (https://shop.top.systems/installatie/accessoires-kabels/perskabelogen/) * Red insulation cap 35 / 50mm², ISKP222N4V02 – to the item (https://shop.top.systems/default.asp?pageid=88&webgroupfilter=16&artdetail=ISKP222N4V02) | category Insulation caps (https://shop.top.systems/installatie/accessoires-kabels/isolatiekappen/) * Insulation cap black 35 / 50mm², ISKP222N4V14 – to the item (https://shop.top.systems/default.asp?pageid=88&webgroupfilter=16&artdetail=ISKP222N4V14) | category Insulation caps (https://shop.top.systems/installatie/accessoires-kabels/isolatiekappen/) * Insulation cap red 70/95mm², ISKP232N4V02 – to the item (https://shop.top.systems/default.asp?pageid=88&webgroupfilter=16&artdetail=ISKP232N4V02) | category Insulation caps (https://shop.top.systems/installatie/accessoires-kabels/isolatiekappen/) * Insulation cap black 70/95mm², ISKP232N4V14 – to the item (https://shop.top.systems/default.asp?pageid=88&webgroupfilter=16&artdetail=ISKP232N4V14) | category Insulation caps (https://shop.top.systems/installatie/accessoires-kabels/isolatiekappen/) * Heat shrink tubing red 50cm for 35/50/70mm battery cable, KRKR01191955 – to the item (https://shop.top.systems/default.asp?pageid=88&webgroupfilter=16&artdetail=KRKR01191955) | category Heat Shrink Tubing (https://shop.top.systems/installatie/accessoires-kabels/krimpkousen/) * Black heat shrink tubing 50cm for 35/50/70mm battery cable, KRKZ01191955 – to the item (https://shop.top.systems/default.asp?pageid=88&webgroupfilter=16&artdetail=KRKZ01191955) | category Heat Shrink Tubing (https://shop.top.systems/installatie/accessoires-kabels/krimpkousen/) * Mega fuse holder M8 35-500A, ZEKHD0000805 – to the item (https://shop.top.systems/default.asp?pageid=88&webgroupfilter=16&artdetail=ZEKHD0000805) | category Fuse holders (https://shop.top.systems/beveiligen-schakelen/zekeringhouders/) * Victron Digital Multi Control 200/200A, REC020005010 – to the article (https://shop.top.systems/default.asp?pageid=88&webgroupfilter=16&artdetail=REC020005010) | category Control panels (https://shop.top.systems/monitoring-controle/bedieningspanelen/) * Victron Digital Multi Control 200/200A GX (90º), DMC000200010R – to the article (https://shop.top.systems/default.asp?pageid=88&webgroupfilter=16&artdetail=DMC000200010R) | category Control panels (https://shop.top.systems/monitoring-controle/bedieningspanelen/) * Victron SmartShunt 500A/50mV, SHU050150050 – to the article (https://shop.top.systems/default.asp?pageid=88&webgroupfilter=16&artdetail=SHU050150050) | Category Battery Monitors (https://shop.top.systems/monitoring-controle/accumonitors/) Related products * MultiPlus-II 48/4500/55-32 230 Volt GX, PMP482406000 – go to the article (https://shop.top.systems/omvormen-laden/omvormen-laden-combi/multiplus-ii-48-4500-55-32-230-volt-gx.html) * MultiPlus-II 48/5000/70-50-GX, PMP482506000 – go to the article (https://shop.top.systems/omvormen-laden/omvormen-laden-combi/multiplus-ii-48-5000-70-50-gx.html) * Quattro-II 48/5000/70-50/50, QUA482504010 – to the article (https://shop.top.systems/omvormen-laden/omvormen-laden-combi/quattro-ii-48-5000-70-50-50.html) Documentation * Datasheet MultiPlus-II inverter/battery charger 4k5 & 6k5 GX 230 V (NL) (https://www.victronenergy.com/upload/documents/Datasheet-MultiPlus-II-4k5-6k5-GX-NL.pdf) * Datasheet MultiPlus-II Inverter/Charger 4k5 & 6k5 GX 230V (EN) (https://www.victronenergy.com/upload/documents/Datasheet-MultiPlus-II-4k5-6k5-GX-EN-.pdf) * Manual MultiPlus-II GX 4k5 6k5 230 V (NL) (https://www.victronenergy.com/upload/documents/MultiPlus-II_4k5_6k5_GX/2983-MultiPlus-II_GX-pdf-nl.pdf) * MultiPlus-II GX 4k5 6k5 230V Manual (EN) (https://www.victronenergy.com/upload/documents/MultiPlus-II_4k5_6k5_GX/2983-MultiPlus-II_GX-pdf-en.pdf) * ISO 9001 Certificate (NL) (https://www.victronenergy.com/upload/documents/ISO9001-certificate-2024-NL.pdf) Contact Would you like to know if the built-in GX version fits your system configuration, or are you unsure about the fuse and cable cross-section? Our product specialists would be happy to calculate your installation for you. Please contact us (https://www.top.systems/nl/contact/). Specifications Nominal battery voltage 48 V Continuous output power at 25 °C 6 kW Continuous output power at 40 °C 5.7 kW Continuous output power at 65 °C 4.6 kW Time-limited power 1 (cold start) 6.5 kW for 4 hours Time-limited power 2 (cold start) 8 kW for 1 hour Peak power 11 kW for 1 minute Maximum battery charging current at 25 °C 100 A Maximum battery charging current at 40 °C 95 A Automatic transfer switch 50 A Maximum AC input current 50 A Auxiliary output Yes, 32 A Maximum apparent feed-in power 6 kW Interfaces BMS-Can, USB, Ethernet, VE.Direct, WiFi Display 2 x 16 characters Input voltage range DC 38 – 60 V Output voltage 230 V AC ± 2 %, 50 Hz ± 0.1 % AC input voltage range 187 – 265 V AC, 45 – 65 Hz Charging voltage absorption / trickle / storage 57.6 / 55.2 / 52.8 V Maximum efficiency 96 % No-load power 28 W No-load power AES mode 18 W No-load power search mode 8 W Compatible battery chemistry LiFePO4, lead-acid, zinc-bromine and more Battery temperature sensor Optional, ASS000001000 External AC current sensor Optional, 100 A Programmable relay Yes, 230 V / 4 A AC; 4 A up to 35 V DC, 1 A up to 60 V DC Communication VE.Bus, 2x general communication ports, remote on/off Operating temperature -40 to +65 °C, fan-assisted cooling Maximum humidity 95 %, non-condensing Maximum altitude 2000 m Housing material Steel Protection class IP21 Battery connection M8 bolts 230 V AC connection Screw terminals 13 mm² Dimensions (hxwxd) 644 x 320 x 150 mm Weight 29 kg Safety standards EN-IEC 60335-1, EN-IEC 60335-2-29, EN-IEC 62109-1, EN-IEC 62109-2 We would be happy to provide you with more information about this product. Please contact us
contact join us.