Available for backorder
€ 23,05 Original price was: €23.05.€ 19,59Current price is: €19.59.
Adler fuse EF3 200Vdc / 175A – We would be happy to provide you with more information about this product. Please contact us.
Available for backorder
Adler fuse EF3 200Vdc / 175A
Battery systems with a high source voltage require more than an ANL or MEGA fuse, which are specified up to 80 Vdc. This fuse protects the battery cable up to 200 Vdc and interrupts short-circuit currents up to 50 kA. The compact bolt mounting fits in ESS and home battery cabinets, in off-grid installations, in the marine sector, and in electric vehicles. Voltage and current Nominal current 175 A. The UL rating of the design is 200 Vdc; Adler itself certifies the same fuse up to 315 Vdc. The breaking capacity is 50 kA at 200 Vdc and 6 kA at 315 Vdc. Tripping behavior and losses The pass-through I²t is 6,600 A²s, measured at 10 x In. The power loss at nominal current is 25.2 W. Note the characteristic curve: the fuse only trips starting from 410% of the nominal current. This makes it a short-circuit protection for the battery cable, not overload protection for a final circuit. Fuse holders The bolt holes are 8.5 mm, intended for M8. Holders with M10 taps are therefore unsuitable. When using a holder with fixed taps, always check the tap diameter first. Construction and standards Designed according to UL 248-20, ISO 8820-8, GB/T 31465, and IEC 60269-7. The series is a UL Recognized Component under file E506668, but not every ampere rating in the series falls under this recognition. Production under IATF 16949, RoHS and REACH compliant. Each fuse bears a QR code for traceability. The vibration test complies with UL 248-20 section 8.6.2.3, test C. Installation The recommended tightening torque is 12 ±1 Nm on M8. In a tight holder, you will not be able to tighten it to the correct torque using a standard open-end wrench: use a torque wrench with a crowfoot attachment. Operating conditions according to the manufacturer: -5 to 40 °C, installation altitude up to 2,000 m, relative humidity up to 50% at 40 °C and up to 90% at 20 °C. For deviating conditions, the derating curve from the datasheet applies. NOTE! These EF3 fuses do not fit in all fuse holders, but usually do fit in an ANL fuse holder. Mounting an EF3 in an MG Master or Victron Distributor is possible. Tightening can be done with an open-end wrench, but preferably tighten to the correct torque using a torque wrench and a crowfoot open-end wrench attachment. Can be used in a LYNX EN DISTRIBUTOR cable lug thickness up to 50mm². Can be ordered directly with this * ANL fuse holder with cover cap, connections 2 x M8 maximum 70mm² crimp eyelet (https://shop.top.systems/beveiligen-schakelen/zekeringhouders/anl-zekeringhouder-met-afdekap-aansluitingen-2-x-m8-maximaal-7.html), ZEKHD0000210 * ANL fuse holder M8 35-600A (https://shop.top.systems/beveiligen-schakelen/zekeringhouders/anl-zekeringhouder-m8-35-600a.html), ZEKHD0000603 * Blue Sea Systems Fuse holder ANL 35A-750A double stud (https://shop.top.systems/beveiligen-schakelen/zekeringhouders/blue-sea-systems-zekeringhouder-anl-35a-750a-dubble-stud.html), ZEKHD0000500 * The full range listed under Fuse Holders (https://shop.top.systems/beveiligen-schakelen/zekeringhouders/) Related products * MG fuse EF3 200Vdc / 100A (https://shop.top.systems/beveiligen-schakelen/zekeringen/mg-zekering-ef3-200vdc-100a.html), MG5001359 * Adler fuse EF3 200Vdc / 150A (https://shop.top.systems/beveiligen-schakelen/zekeringen/adler-zekering-ef3-200vdc-150a.html), MG5001323 * Adler fuse EF3 200Vdc / 200A (https://shop.top.systems/beveiligen-schakelen/zekeringen/adler-zekering-ef3-200vdc-200a.html), MG5001325 * Adler fuse EF3 200Vdc / 250A (https://shop.top.systems/beveiligen-schakelen/zekeringen/adler-zekering-ef3-200vdc-250a.html), MG5001326 * Adler fuse EF3 200Vdc / 300A (https://shop.top.systems/beveiligen-schakelen/zekeringen/adler-zekering-ef3-200vdc-300a.html), MG5001327 * Adler fuse EF3 200Vdc / 350A (https://shop.top.systems/beveiligen-schakelen/zekeringen/adler-zekering-ef3-200vdc-350a.html), MG5001328 Documentation * Datasheet Adler EF3 200Vdc (EN) (https://shop.top.systems/_clientfiles/Documents/Datasheets/EF3_200Vdc.pdf) Question & Answer QuestionAnswerUp to what voltage may I use this fuse? 200 Vdc according to the UL value. Adler itself certifies the design up to 315 Vdc, with a breaking capacity of 6 kA at that level. Can I use it as overload protection for a final circuit? No. The datasheet indicates tripping from 410% In, so the fuse is intended as short-circuit protection for the battery bank and the battery cable. What is the correct tightening torque? 12 ±1 Nm on the M8 bolts, according to the datasheet. What current I²t should I maintain? 6,600 A²s, measured by the manufacturer at 10 x the nominal current. How much heat does the fuse generate at full load? 25.2 W at nominal current. Take this into account in a closed enclosure. Is the series suitable for vehicles subject to vibration loads? Yes. The fuses comply with the vibration test of UL 248-20 section 8.6.2.3, test C. Does the UL approval apply to every value in the series? No. The file is E506668, but the datasheet marks some of the ampere values as not certified. May I install the fuse above 2,000 m? No, not without consultation. The manufacturer specifies 2,000 m as the upper limit and refers to Adler itself for deviating conditions. Contact Feel free to call or email before ordering. We are happy to help you consider the fuse value, the appropriate holder, and the cable connection in your installation, and are willing to review a schematic or drawing with you. Contact Top Systems (https://www.top.systems/nl/contact/). Specifications Nominal current 175 A Nominal voltage (UL) 200 Vdc Nominal voltage (self-certified) 315 Vdc Breaking capacity 50 kA at 200 Vdc, 6 kA at 315 Vdc Trip value from 410 % In Flow-through I²t 6,600 A²s at 10 x In Power loss 25.2 W at 1.0 In Connection 2 bolt holes M8, hole diameter 8.5 mm Tightening torque 12 ±1 Nm Construction type 36x22 Length 77 mm Standards UL 248-20, ISO 8820-8, GB/T 31465, IEC 60269-7 UL dossier E506668 Vibration test UL 248-20, 8.6.2.3 test C Ambient temperature -5 to +40 °C Maximum installation height 2,000 m Production and environment IATF 16949, RoHS and REACH Manufacturer Adler Elektrotechnik EAN 6153548399311
We'd be happy to provide you with more information about this product. Please contact us.
www.robust-mt.nl