Adler fuse EF3 200Vdc / 100A

Available for backorder

Original price was: €23.05.Current price is: €19.59.

Adler fuse EF3 200Vdc / 100A – We would be happy to provide you with more information about this product. Please contact us.

SKU: MG5001359 Categories: , , Brand: Brand:
MG5001359

Available for backorder

Description

Adler fuse EF3 200Vdc / 100A

Adler fuse EF3 200Vdc / 100A

Protection of a branch or a separate battery directly on the battery side, where a lithium battery can deliver a very high current in the event of a short circuit. The low nominal current makes the fuse suitable for cables to a charge controller, a DC-DC converter, or a smaller inverter in 12, 24, and 48 V installations, in ESS, marine, and vehicles. Suitable battery voltages. Nominal voltage 200 Vdc. This makes the fuse suitable for use in 12, 24, and 48 V battery systems and in high-voltage systems up to 200 Vdc. In practice, the permissible system voltage is limited by the fuse holder: ANL holders are typically specified up to 32 or 60 Vdc. Current and breaking capacity of 100 A. Nominal current 100 A, breaking capacity 50 kA at 200 Vdc. The fuse is intended as short-circuit protection for the battery cable. Total I²t 1,530 A²s (measured at 10 × In), power loss 14.5 W. Construction: Bolt fuse in size 36×22 with two M8 terminals and a length of 77 mm. Designed according to UL 248-20, ISO 8820-8, GB/T 31465 and IEC 60269-7, manufactured under IATF 16949. Each fuse has a QR code for traceability. PLEASE NOTE! These EF3 fuses do not fit in all fuse holders, but usually do fit in an ANL fuse holder. It is possible to mount an EF3 in an MG Master or Victron Distributor. Tightening can be done with a spanner, but preferably torqued using a torque wrench and a crowfoot spanner attachment. Can be used in a LYNX EN DISTRIBUTOR up to 50mm² cable lug thickness. Installation The EF3 does not fit in every fuse holder; it usually does in an ANL holder with M8 studs. Tighten the nuts to 12 ±1.0 Nm, preferably with a torque wrench and a crowfoot tool. Ambient temperature -5 to +40 °C, installation altitude up to 2000 m. Take into account 14.5 W of heat dissipation in a closed enclosure. Question & Answer QuestionAnswer Can the fuse be used in a 12, 24, or 48 V system?Yes. The nominal voltage is 200 Vdc. The maximum system voltage is determined by the fuse holder used. How much heat does the fuse generate?14.5 W according to the manufacturer. Take this into account when installing it in a closed enclosure or cabinet. Is a 50 kA breaking capacity sufficient for a LiFePO4 battery bank?The breaking capacity must be higher than the maximum short-circuit current of the battery bank. Compare the 50 kA with the short-circuit current specified by the battery manufacturer. Does the fuse fit in a Victron Lynx Distributor? Victron designs the Victron Lynx Distributor M10 (https://shop.top.systems/accu-s/accessoires-accu-s/victron-lynx-distributor-m10.html), LYN060102010 for MEGA fuses. An EF3 falls outside that specification from Victron. What torque do you use to tighten the fuse? 12 ±1.0 Nm on the M8 terminals. Can be ordered directly with this * ANL fuse holder M8 35-600A (https://shop.top.systems/beveiligen-schakelen/zekeringhouders/anl-zekeringhouder-m8-35-600a.html), ZEKHD0000603 * Blue Sea Systems Fuse holder ANL 35A-750A double stud (https://shop.top.systems/beveiligen-schakelen/zekeringhouders/blue-sea-systems-zekeringhouder-anl-35a-750a-dubble-stud.html), ZEKHD0000500 * ANL fuse holder with cover cap, 2 x M8, maximum 70mm² crimp eyelet (https://shop.top.systems/beveiligen-schakelen/zekeringhouders/anl-zekeringhouder-met-afdekap-aansluitingen-2-x-m8-maximaal-7.html), ZEKHD0000210 * All holders: Fuse holders (https://shop.top.systems/beveiligen-schakelen/zekeringhouders/) Related products * Adler fuse EF3 200Vdc / 150A (https://shop.top.systems/beveiligen-schakelen/zekeringen/adler-zekering-ef3-200vdc-150a.html), MG5001323 * Adler fuse EF3 200Vdc / 175A (https://shop.top.systems/beveiligen-schakelen/zekeringen/adler-zekering-ef3-200vdc-175a.html), MG5001324 * Adler fuse EF3 200Vdc / 200A (https://shop.top.systems/beveiligen-schakelen/zekeringen/adler-zekering-ef3-200vdc-200a.html), MG5001325 * Adler fuse EF3 200Vdc / 250A (https://shop.top.systems/beveiligen-schakelen/zekeringen/adler-zekering-ef3-200vdc-250a.html), MG5001326 * Adler fuse EF3 200Vdc / 300A (https://shop.top.systems/beveiligen-schakelen/zekeringen/adler-zekering-ef3-200vdc-300a.html), MG5001327 * Adler fuse EF3 200Vdc / 350A (https://shop.top.systems/beveiligen-schakelen/zekeringen/adler-zekering-ef3-200vdc-350a.html), MG5001328 Documentation * Datasheet EF3 EV Fuse (EN) – ADLER Electric (https://pim.adlerelectric.com/thumbnails/catalog/5/9/6/e/596e6c691f7d67cedfe68856572d6bc2133eb8d8_EF3_datasheet_20250826.pdf) * Product page EF3 EV Fuse (EN) – ADLER Electric (https://www.adlerelectric.com/product/EF3/) * Datasheet EF3 200Vdc (EN) (https://shop.top.systems/_clientfiles/Documents/Datasheets/EF3_200Vdc.pdf) * Lithium-Ion batteries and fuses (EN) – MG Energy Systems (https://docs.mgenergysystems.eu/papers/fuses) Contact Are you unsure about the correct fuse rating, holder, or short-circuit current of the battery bank? Feel free to contact us. We are willing to review the schematic and the complete DC distribution with you. Please contact Top Systems (https://www.top.systems/nl/contact/). Specifications Nominal current 100 A Nominal voltage 200 Vdc Breaking capacity 50 kA at 200 Vdc I²t total (10 × In) 1,530 A²s Power loss 14.5 W Connection 2 x M8 Tightening torque 12 ±1.0 Nm Overall size 36x22 Length 77 mm Ambient temperature -5 to +40 °C Installation height max. 2000 m Standards UL 248-20, ISO 8820-8, GB/T 31465, IEC 60269-7 Certification mark UL Recognized Component (E506668) Quality system IATF 16949 Environment RoHS, REACH Manufacturer type number EF33100220 Manufacturer ADLER Elektrotechnik Leipzig GmbH

We'd be happy to provide you with more information about this product. Please contact us.