Adler fuse EF3 200Vdc / 300A

Available for backorder

Original price was: €23.05.Current price is: €19.59.

Adler fuse EF3 200Vdc / 300A – We would be happy to provide you with more information about this product. Please contact us.

SKU: MG5001327 Categories: , , Brand: Brand:
MG5001327

Available for backorder

Description

Adler fuse EF3 200Vdc / 300A

Adler fuse EF3 200Vdc / 300A

Large lithium battery banks deliver currents of tens of thousands of amperes in the event of a short circuit. This fuse trips up to 50 kA at a voltage of up to 200 Vdc and belongs on the main cable between the battery bank and the distribution panel. Applications include ESS and commercial battery cabinets, off-grid installations, marine applications, and electric vehicles with an M8 bolt connection. Voltage and current: Nominal current 300 A at 200 Vdc, with a breaking capacity of 50 kA. Unlike values ​​up to and including 250 A, this fuse does not have a self-certified 315 Vdc rating; it is not specified above 200 Vdc. Tripping behavior and losses: The pass-through I²t is 29,000 A²s, measured at 10 x In. The power loss at nominal current is 34.3 W, more than a third higher than at the 175 A rating. Note the characteristics: the fuse only trips starting from 410% of the nominal current. This is therefore short-circuit protection for the battery bank and the battery cable, not overload protection for a final circuit. Fuse holders The bolt holes are 8.5 mm, intended for M8. Holders with M10 taps are therefore unsuitable. For 300 A, also check whether the holder itself is specified for that current and whether the crimp cable eye fits next to the fuse. Construction and standards Designed according to UL 248-20, ISO 8820-8, GB/T 31465 and IEC 60269-7. The series is a UL Recognized Component under file E506668, but not every ampere rating in the series falls under this recognition. Production under IATF 16949, RoHS and REACH compliant. Each fuse bears a QR code for traceability. The vibration test complies with UL 248-20 section 8.6.2.3, test C. NOTE! These EF3 fuses do not fit in all fuse holders, but usually do fit in an ANL fuse holder. It is possible to mount an EF3 in an MG Master or Victron Distributor. Tightening can be done with a spanner, but preferably torqued using a torque wrench and a crowfoot spanner attachment. Can be used in a LYNX EN DISTRIBUTOR up to 50mm² cable lug thickness. Installation: The recommended tightening torque is 12 ±1 Nm on M8. In a tight holder, you will not be able to torque it correctly with a standard spanner: use a torque wrench with a crowfoot attachment. A poor clamp connection is the primary source of heat at 300 A. Operating conditions according to the manufacturer: -5 to 40 °C, installation altitude up to 2,000 m, relative humidity up to 50% at 40 °C and up to 90% at 20 °C. For deviating conditions, the derating curve from the datasheet applies. Can be ordered directly with this * ANL fuse holder M8 35-600A (https://shop.top.systems/beveiligen-schakelen/zekeringhouders/anl-zekeringhouder-m8-35-600a.html), ZEKHD0000603 * Blue Sea Systems Fuse holder ANL 35A-750A double stud (https://shop.top.systems/beveiligen-schakelen/zekeringhouders/blue-sea-systems-zekeringhouder-anl-35a-750a-dubble-stud.html), ZEKHD0000500 * ANL fuse holder with cover cap, connections 2 x M8 maximum 70mm² crimp eyelet (https://shop.top.systems/beveiligen-schakelen/zekeringhouders/anl-zekeringhouder-met-afdekap-aansluitingen-2-x-m8-maximaal-7.html), ZEKHD0000210 * The full range listed under Fuse Holders (https://shop.top.systems/beveiligen-schakelen/zekeringhouders/) Related products * MG fuse EF3 200Vdc / 100A (https://shop.top.systems/beveiligen-schakelen/zekeringen/mg-zekering-ef3-200vdc-100a.html), MG5001359 * Adler fuse EF3 200Vdc / 150A (https://shop.top.systems/beveiligen-schakelen/zekeringen/adler-zekering-ef3-200vdc-150a.html), MG5001323 * Adler fuse EF3 200Vdc / 175A (https://shop.top.systems/beveiligen-schakelen/zekeringen/adler-zekering-ef3-200vdc-175a.html), MG5001324 * Adler fuse EF3 200Vdc / 200A (https://shop.top.systems/beveiligen-schakelen/zekeringen/adler-zekering-ef3-200vdc-200a.html), MG5001325 * Adler fuse EF3 200Vdc / 250A (https://shop.top.systems/beveiligen-schakelen/zekeringen/adler-zekering-ef3-200vdc-250a.html), MG5001326 * Adler fuse EF3 200Vdc / 350A (https://shop.top.systems/beveiligen-schakelen/zekeringen/adler-zekering-ef3-200vdc-350a.html), MG5001328 Documentation * Datasheet Adler EF3 200Vdc (EN) (https://shop.top.systems/_clientfiles/Documents/Datasheets/EF3_200Vdc.pdf) Question & Answer QuestionAnswerUp to what voltage may I apply this value?200 Vdc. The self-certified 315 Vdc value applies only to values ​​up to and including 250 A, not to this one. Can I use it as overload protection for a final circuit?No. The datasheet indicates tripping from 410% In, so the fuse is intended as short-circuit protection for the battery bank and the battery cable. What is the correct tightening torque?12 ±1 Nm on the M8 bolts, according to the datasheet. Which current-I²t should I maintain?29,000 A²s, measured by the manufacturer at 10 x the nominal current. How much heat does the fuse generate at full load?34.3 W at nominal current. Take this into account in a closed enclosure and when choosing the holder. Is the series suitable for vehicles subject to vibration loads? Yes. The fuses comply with the vibration test of UL 248-20 section 8.6.2.3, test C. Does the UL approval apply to every value in the series? No. The file is E506668, but the datasheet marks some of the ampere values ​​as not certified. May I install the fuse above 2,000 m? No, not without consultation. The manufacturer specifies 2,000 m as the upper limit and refers to Adler itself for deviating conditions. Contact Feel free to call or email before ordering. We are happy to review the fuse value, the appropriate holder, and the cable connection in your installation with you, and are willing to go through a schematic or drawing with you. Contact Top Systems (https://www.top.systems/nl/contact/). Specifications Nominal current 300 A Nominal voltage 200 Vdc Breaking capacity 50 kA at 200 Vdc Trip value from 410 % In Flow rate I²t 29,000 A²s at 10 x In Power loss 34.3 W at 1.0 In Connection 2 bolt holes M8, hole diameter 8.5 mm Tightening torque 12 ±1 Nm Construction type 36x22 Length 77 mm Standards UL 248-20, ISO 8820-8, GB/T 31465, IEC 60269-7 UL dossier E506668 Vibration test UL 248-20, 8.6.2.3 test C Ambient temperature -5 to +40 °C Maximum installation height 2,000 m Production and environment IATF 16949, RoHS and REACH Manufacturer Adler Elektrotechnik EAN6153548481443

We'd be happy to provide you with more information about this product. Please contact us.