Available for backorder
€ 665,69 Original price was: € 665.69.€ 565,84Current price is: € 565.84.
Hoppecke Sun Power VL 2-1220 – We'd be happy to provide you with more information about this product. Please contact us.
Available for backorder
Hoppecke sun power VL 2-1220
Hoppecke sun | power VL 2-1220 — 2V OPzS Tubular Plate Cell Closed (vented) lead-acid cell with tubular plates and liquid electrolyte, developed for heavy cyclic operation in off-grid, hybrid, and peak-shaving applications. The cell withstands prolonged partial charge operation (PSoC) and deep discharge, and achieves a design life of over 20 years with proper charging and 20°C. Key features * Tubular plate positive electrode with polyester sheath, lead-selenium/low-antimony lattice * Up to 1500 cycles at 80% DoD; according to IEC 61427 up to approx. 2400 cycles * Design service life >20 years at 20 °C, >10 years at 30 °C, >5 years at 40 °C * High charging current acceptance, suitable for PSoC operation * Standard prepared for electrolyte circulation (sun | air) * Low self-discharge, insensitive to incidental deep discharge * Dimensions according to DIN 40736-1; manufactured according to EN/IEC 60896-11 and IEC 61427 * Fully recyclable via closed loop Applications * Off-grid and hybrid energy storage (residential, commercial, agricultural) * Peak shaving and voltage stabilization * Village and island power supplies, telecom stations * Pumping systems and cathodic corrosion protection * Long-term emergency power where cycle stability and standby characteristics come together Versions * Filled and charged — ready for immediate commissioning after test charge * Dry pre-charged — for long-term storage or container/air transport; Filling with dilute sulfuric acid, density 1.24 kg/l at 20 °C (higher in cold climate, lower in warm climate). Bank construction and system voltage. Cells are connected in series to the desired system voltage. The cell has two positive and two negative M10 inserts, which allows for parallel strings and low contact resistance. * 12 V bank = 6 cells * 24 V bank = 12 cells * 48 V bank = 24 cells — approx. 58.6 kWh gross (C100), approx. 29 kWh usable at 50% DoD Charging settings (indicative, see manual) Parameter Per cell 24V bank 48V bank Float / trickle charge 2.23 V 26.8 V 53.5 V Absorption / boost 2.40 V 28.8 V 57.6 V Discharge end voltage (>10 h) 1.98 V 23.8 V 47.5 V Discharge end voltage (1 h) 1.81 V 21.7 V 43.4 V * Temperature compensation approx. −4 mV per cell per K above 20 °C — temperature sensor strongly recommended * Recommended charging current 0.1–0.2 × C10 (I10 = 91.5 A); Higher currents are permissible according to the manual * Maximum 80% DoD; fully recharge at least every two weeks to prevent sulfation * Perform equalization charging periodically in accordance with Hoppecke guidelines * A Victron Battery Balancer is not applicable: it balances 12V blocks, not individual 2V cells. Monitoring is performed via midpoint monitoring on the battery monitor. Installation and safety * Closed cell: hydrogen is produced during charging. Ventilate the installation area in accordance with EN IEC 62485-2; never place in a closed cabinet * Acid-resistant substrate, drip tray if locally required * Safety distance to sparking or hot parts (max. surface temperature 300 °C) * Not in direct sunlight or near heat sources; humidity maximum 85% * Optimal operating temperature range 10–30 °C * Dimension series connectors, cell bridges, and battery racks for the maximum discharge current Maintenance * Under normal operation and 20 °C, only top up with demineralized water every 2–3 years * With a recombination system or electrolyte recirculation, top-up intervals increase further * Periodically check and log cell voltages, electrolyte level, and terminal connections Available to order directly * Victron BMV-712 Smart battery monitor — art. BAM030712000 (https://shop.top.systems/catalogsearch/result/?q=BAM030712000) — includes midpoint monitoring of the bank (category: Battery monitors (https://shop.top.systems/catalogsearch/result/?q=accumonitor)) * Victron SmartShunt 500A/50mV — art. SHU050150050 (https://shop.top.systems/catalogsearch/result/?q=SHU050150050) — alternative without display, read out via VictronConnect or GX (category: Battery monitors (https://shop.top.systems/catalogsearch/result/?q=accumonitor)) * Victron temperature sensor for BMV-702/712 and SmartShunt — art. ASS000100000 (https://shop.top.systems/catalogsearch/result/?q=ASS000100000) — necessary for temperature-compensated charging (category: Sensors (https://shop.top.systems/catalogsearch/result/?q=sensor)) * Victron MultiPlus-II 48/5000/70-50 230V — art. PMP482505010 (https://shop.top.systems/catalogsearch/result/?q=PMP482505010) — inverter/charger for a 24-cell 48V bank (category: Inversion/charging combo (https://shop.top.systems/catalogsearch/result/?q=multiplus-II)) * Hoppecke cell connectors, terminal covers and battery racking — composition depends on the installation plan, to be calculated upon request * Hoppecke grid | aquagen pro max recombination plugs or sun | air electrolyte circulation — upon request Related products Other capacities within the same 2V OPzS series: * sun | power VL 2-280 — art. BAT300000280 (https://shop.top.systems/catalogsearch/result/?q=BAT300000280) * sun | power VL 2-1070 — art. BAT300001070 (https://shop.top.systems/catalogsearch/result/?q=BAT300001070) * sun | power VL 2-1520 — art. BAT300001520 (https://shop.top.systems/catalogsearch/result/?q=BAT300001520) * sun | power VL 2-1820 — art. BAT300001820 (https://shop.top.systems/catalogsearch/result/?q=BAT300001820) * sun | power VL 2-2170 — art. BAT300002170 (https://shop.top.systems/catalogsearch/result/?q=BAT300002170) * sun | power VL 2-2540 — art. BAT300002540 (https://shop.top.systems/catalogsearch/result/?q=BAT300002540) * sun | power VL 2-2900 — art. BAT300002900 (https://shop.top.systems/catalogsearch/result/?q=BAT300002900) * sun | power VL 2-3610 — art. BAT300003610 (https://shop.top.systems/catalogsearch/result/?q=BAT300003610) * sun | power VL 12-70 (12V block version) — art. BAT300120070 (https://shop.top.systems/catalogsearch/result/?q=BAT300120070) Maintenance-free alternative: the enclosed OPzV version sun | power VR L — see the Traction batteries category (https://shop.top.systems/accu/tractie.html) or the full battery range (https://shop.top.systems/accu.html). Manuals, datasheets and documentation * Hoppecke sun | power VL — installation, commissioning and operating manual (EN) (https://www.hoppecke.com/fileadmin/Redakateur/Hoppecke-Main/Products-Import/vl_manual_en.pdf) * Hoppecke — assembly manual sealed (VLA) lead-acid batteries, incl. ventilation calculation (EN) (https://www.hoppecke.com/fileadmin/Redakateur/Hoppecke-Main/Products/Downloads/Montagehandbuch_geschl_EN_final.pdf) * Hoppecke sun | power VL — brochure with capacities, dimensions, and weights (EN) (https://www.hoppecke.com/fileadmin/Redakneur/Hoppecke-Main/Products-Import/sun_power_vl_brochure_en.pdf) * Hoppecke sun | power VL — brochure (DE) (https://www.hoppecke.com/fileadmin/Redakneur/Hoppecke-Main/Products-Import/sun_power_vl_brochure_de.pdf) We supply the Declaration of Conformity, CE documentation, and the recycling declaration with the order upon request. Videos Hoppecke does not publish product videos for this series. For the correct charging and monitoring of a lead-acid battery bank using Victron equipment, the following English-language videos from Victron Energy are relevant: * Victron training videos — including "Batteries and Battery Monitoring" and "Maximising Lead Acid Battery Life" (https://www.victronenergy.com/blog/2021/06/08/victron-training-videos/) * Victron online training with exam and certificate (https://www.victronenergy.com/information/training) * Victron Tech — technical and training videos (https://www.youtube.com/@victrontech/videos) * Victron Energy — official YouTube channel (https://www.youtube.com/channel/UCMWYxDjwpyQGw6zg5p9SNhw) Need advice or a quote? An OPzS bank is custom-made: cell count, configuration, connector sets, ventilation, and charging strategy together determine whether you achieve a lifespan of twenty years or five years. We calculate your battery bank, size the Victron charging equipment accordingly, and deliver complete with connectors and battery racking. Contact us via our contact form (https://shop.top.systems/contacts) and you will receive a technically substantiated quotation within one working day. Specifications Article number BAT300001220 Brand / series Hoppecke sun | power VL Type OPzS, closed (vented) lead-acid, tubular plate Nominal voltage 2 V Capacity C100 (1.85 V/cell) 1220 Ah Capacity C10 (1.80 V/cell) 915 Ah I10 91.5 A Cycle expectation up to 1500 cycles at 80% DoD; approx. 2400 cycles according to IEC 61427 Design service life >20 years at 20 °C, >10 years at 30 °C, >5 years at 40 °C Maximum discharge depth 80% Float voltage 2.23 V/cell at 20 °C Absorption voltage 2.40 V/cell Temperature compensation approx. −4 mV/cell/K Discharge end voltage 1.98 V/cell (>10 h) / 1.81 V/cell (1 h) Electrolyte diluted sulfuric acid, density 1.24 kg/l at 20 °C Connection insert M10, 2× plus / 2× minus Maintenance interval water top up every 2–3 years at 20 °C Optimal operating temperature 10–30 °C Dimensions (l × w × h) 215 × 193 × 710 mm Weight filled 63.1 kg Weight dry pre-charged 45.8 kg Standards DIN 40736-1, EN/IEC 60896-11, IEC 61427 EAN 6011640310378
We'd be happy to provide you with more information about this product. Please contact us.
www.robust-mt.nl