Victron BlueSolar MPPT 150/70-MC4 (12/24/48V)

Available for backorder

Original price was: € 453.75.Current price is: € 385.69.

Victron BlueSolar MPPT 150/70-MC4 (12/24/48V) – We'd be happy to provide you with more information about this product. Please contact us.

SKU: SCC010070300 Categories: , , Brand: Brand:
SCC010070300

Available for backorder

Victron BlueSolar MPPT 150/70-MC4 (12/24/48V)

Victron BlueSolar MPPT 150/70-MC4 (12/24/48V) For larger onboard solar power installations, on company premises, or in remote locations where an extensive panel field is connected directly using MC4 connectors. Suitable for lead-acid and lithium batteries, with shadow detection and BatteryLife. Ultra-fast MPPT with shadow detection. The ultra-fast MPPT algorithm continuously monitors the voltage and current of the panel field and maintains the maximum power point, even in rapidly changing cloud conditions. In partial shading, multiple power peaks can occur on the voltage curve; advanced shadow detection actively seeks the highest peak instead of remaining at a lower local maximum. Maximum efficiency 98%. Direct MC4 connection * Two pairs of MC4 connectors, internally parallel-connected to one MPPT tracker * Maximum 30 A per MC4 connection * Maximum PV open-circuit voltage 150 V absolute (coldest conditions), 145 V at start-up and operation * Maximum PV short-circuit current 50 A * Protected against reverse PV polarity Power and battery voltage * Maximum charging current 70 A * Automatic selection 12, 24 or 48 V; 36 V manually adjustable * Nominal PV output 1000 W at 12 V, 2000 W at 24 V, 3000 W at 36 V and 4000 W at 48 V * Battery terminals up to 35 mm² / AWG2 * Self-consumption <35 mA at 12 V and <20 mA at 48 V Adaptive charging and BatteryLife The charge controller operates with an adaptive multi-stage charging algorithm with eight pre-programmed battery profiles and a fully user-configurable profile. The absorption time is determined by the battery voltage at startup. The BatteryLife algorithm adjusts the charging threshold daily when the battery does not structurally reach full charge, thus preventing deep discharge and premature aging. Temperature compensation -16, -32 or -64 mV/°C, depending on the system voltage. Programmable relay and remote control The programmable DPST relay (AC 4 A up to 240 Vac, DC 4 A up to 35 Vdc, and 1 A up to 60 Vdc) can be used for applications including a generator alarm or switching a dump load. Additionally, a remote two-pole on/off connection is available, for example, for control from a battery management system using the VE.Direct non-inverting remote on-off cable (ASS030550320) (https://shop.top.systems/installatie/kabels/remote-control/victron-ve-direct-non-inverting-remote-on-off-cable.html). Parallel operation of multiple charge controllers is possible, but not synchronized. Reading and monitoring The controller can be read and configured via the VE.Direct port. With the VE.Direct Bluetooth Smart dongle (ASS030536011) (https://shop.top.systems/monitoring-controle/draadloos/victron-ve-direct-bluetooth-smart-dongle.html), you wirelessly connect the controller to VictronConnect on a smartphone or tablet; this is done on a PC via the VE.Direct to USB interface (ASS030530010) (https://shop.top.systems/installatie/interface/victron-ve-direct-to-usb-interface.html). For fixed readings, the MPPT Control (SCC900500000) (https://shop.top.systems/monitoring-controle/bedieningspanelen/victron-mppt-control.html) is available. When connected to a GX device, output and battery status appear in the VRM Portal – Victron Energy (https://vrm.victronenergy.com/login). Installation and environment * Protected against output short circuit and overtemperature * Protection class IP43 for the electronics and IP22 for the connection area * Operating temperature -30 to +60 °C, full power up to 40 °C * Maximum installation altitude 5000 m, full power up to 2000 m * Internal temperature sensor for charging voltage compensation Available to order directly * Cable set 35mm² 1.5 m red and black M8 (KABSET010350) (https://shop.top.systems/installatie/kabels/accu/kabelset-35mm-1-5-mtr-rood-en-zwart-m8.html) * Victron VE.Direct non-inverting remote on-off cable (ASS030550320) (https://shop.top.systems/installatie/kabels/remote-control/victron-ve-direct-non-inverting-remote-on-off-cable.html) * Victron VE.Direct Bluetooth Smart dongle (ASS030536011) (https://shop.top.systems/monitoring-control/draadloos/victron-ve-direct-bluetooth-smart-dongle.html) * Victron VE.Direct cable 10m (ASS030530310) (https://shop.top.systems/installation/cables/communication/victron-ve-direct-kabel-10m.html) * Victron VE.Direct to USB interface (ASS030530010) (https://shop.top.systems/installation/interface/victron-ve-direct-to-usb-interface.html) * Victron MPPT Control (SCC900500000) (https://shop.top.systems/monitoring-control/controlpanels/victron-mppt-control.html) * More accessories in the Solar panel accessories category (https://shop.top.systems/zonnestroom/accessories-zonnepanelen/) Related products * Victron BlueSolar MPPT 150/60-MC4 (12/24/48V) (SCC010060300) (https://shop.top.systems/zonnestroom/omvormers-zonnepanelen/victron-bluesolar-mppt-150-60-mc4-12-24-48v.html) * Victron BlueSolar MPPT 150/70-Tr (12/24/48V) (SCC010070200) (https://shop.top.systems/zonnestroom/omvormers-zonnepanelen/victron-bluesolar-mppt-150-70-tr-12-24-48v.html) — the same controller with screw terminals instead of MC4 * The full range can be found in the category Solar panel inverters (https://shop.top.systems/zonnestroom/omvormers-zonnepanelen/) Documentation * Manual BlueSolar MPPT 150/60 & 150/70 (HTML, NL) (https://www.victronenergy.com/media/pg/Manual_BlueSolar_150-60__150-70/nl/index-nl.html) * BlueSolar MPPT 150/60 & 150/70 Manual (PDF, NL) (https://www.victronenergy.com/upload/documents/Manual_BlueSolar_150-60__150-70/29694-MPPT_solar_charger_manual-pdf-nl.pdf) * BlueSolar MPPT 150/60 & 150/70 Manual (HTML, EN) (https://www.victronenergy.com/media/pg/Manual_BlueSolar_150-60__150-70/en/index-en.html) * BlueSolar MPPT Manual 150/60 & 150/70 (PDF, EN) (https://www.victronenergy.com/upload/documents/Manual_BlueSolar_150-60__150-70/29694-MPPT_solar_charger_manual-pdf-en.pdf) * Datasheet BlueSolar Charge Controller MPPT 150/60 & 150/70 (NL) (https://www.victronenergy.com/upload/documents/Datasheet-BlueSolar-charge-controller-MPPT-150-60-and-150-70-NL.pdf) * Datasheet BlueSolar Charge Controllers MPPT 150/60 & 150/70 (EN) (https://www.victronenergy.com/upload/documents/Datasheet-BlueSolar-charge-controller-MPPT-150-60-and-150-70-EN.pdf) * Datasheet BlueSolar and SmartSolar Charge Controller MPPT – Overview (EN) (https://www.victronenergy.com/upload/documents/Datasheet-BlueSolar-and-SmartSolar-charge-controller-overview-EN.pdf) * Dimensioning Drawing BlueSolar MPPT 150/60 & 150/70 MC4 (PDF) (https://www.victronenergy.com/upload/documents/DimensionDrawing-BlueSolar-150_60-&-150_70-MC4.pdf) * Dimensioning Drawing BlueSolar MPPT 150/60 & 150/70 MC4 (3D) (https://www.victronenergy.com/upload/documents/DimensionDrawing-BlueSolar-150_60-&-150_70-MC4-3D.pdf) * Dimensioning drawing BlueSolar MPPT 150/60 & 150/70 MC4 (STP) (https://www.victronenergy.com/upload/documents/DimensionDrawing-BlueSolar-150_60-&-150_70-MC4-3D.STEP) * Declaration of Conformity BlueSolar MPPT 150/70-MC4 EU and UK (https://www.victronenergy.com/upload/documents/BlueSolar-MPPT-150-70-MC4-EU-and-UK-2024-02-16.pdf) * Safety Certificate IEC 62109-1 – MPPT 150/45, 150/60 & 150/70 Tr and MC4 (https://www.victronenergy.com/upload/documents/Certificate-Safety-IEC-62109-1-MPPT-150-45,-150-60-&-150-70-Tr-en-MC4.pdf) * Safety Certificate IEC 62109-1 AS/NZS – MPPT 150/45, 150/60 & 150/70 Tr and MC4 (https://www.victronenergy.com/upload/documents/Certificate-Safety-IEC-62109-1-AS-NZS-BlueSolar–SmartSolar-MPPT-150-45,-150-60–150-70-Tr-MC4-and-addendum.pdf) * VE.Direct Protocol (https://www.victronenergy.com/upload/documents/VE.Direct-Protocol-3.34.pdf) * VE.Direct HEX Protocol MPPT (https://www.victronenergy.com/upload/documents/BlueSolar-HEX-protocol.pdf) * Technical information: PWM or MPPT? (https://www.victronenergy.com/upload/documents/Technical-Information-Which-solar-charge-controller-PWM-or-MPPT.pdf) Videos * Victron MPPT charge controllers (EN) (https://www.victronenergy.com/upload/documents/Promo%20videos/Ad%20videos/MPPT/16×9/EN_MPPT.mp4) * Did you know… why the MPPT charge controller starts 5 Vdc above the battery voltage? (https://www.youtube.com/watch?v=EVAvRs32TiE) * How to get a readout from an MPPT with a VE.Direct Bluetooth Smart dongle (https://www.youtube.com/watch?v=vZJA4eTd6vw) * VictronConnect: how to change MPPT settings (https://www.youtube.com/watch?v=ve59J9WTm1E) * VictronConnect: MPPT live data (https://www.youtube.com/watch?v=8yJyFZuDkuA) Contact Would you like to know how many panels you can connect to this controller, or which fuse and cable cross-section are suitable for your installation? Our specialists would be happy to calculate it for you and advise on mounting and monitoring. Contact us via top.systems/nl/contact (https://www.top.systems/nl/contact/). Specifications Battery voltage 12, 24 or 48 V automatic; 36 V manual Maximum charging current 70 A Nominal PV power 12 V 1000 W Nominal PV power 24 V 2000 W Nominal PV power 36 V 3000 W Nominal PV power 48 V 4000 W Max. PV open-circuit voltage 150 V absolute maximum; 145 V at start and operation Max. PV short-circuit current 50 A PV connection 2 pairs of MC4 connectors, max. 30 A per connection Maximum efficiency 98% Self-consumption 12 V: <35 mA / 48 V: <20 mA Charging algorithm multi-stage adaptive, eight pre-programmed profiles or user-defined Charging voltage absorption 14.4 / 28.8 / 43.2 / 57.6 V Charging voltage float 13.8 / 27.6 / 41.4 / 55.2 V Charging voltage equalization 16.2 / 32.4 / 48.6 / 64.8 V Temperature compensation -16 / -32 / -64 mV/°C Protection reverse PV polarity, output short circuit, overtemperature Data communication VE.Direct port Remote on/off yes, two-pole connection Programmable relay DPST; AC 4 A up to 240 Vac, DC 4 A up to 35 Vdc and 1 A up to 60 Vdc Parallel operation yes, not synchronized Battery terminals 35 mm² / AWG2 Protection class IP43 (electronics), IP22 (connection area) Operating temperature -30 to +60 °C (full power up to 40 °C) Humidity 95%, non-condensing Maximum altitude 5000 m (full power up to 2000 m) Ambient condition indoor installation type 1, unconditioned Pollution degree PD3 Color blue (RAL 5012) Dimensions (hxwxd) 215 x 250 x 95 mm Weight 3 kg Safety standards EN/IEC 62109-1, UL 1741, CSA C22.2 EAN 8719076025528 We would be happy to provide you with more information about this product. Please contact us contact join us.
an electric sloop? See our full range.