Victron Cyrix-ct combiner relay 12/24V-120A

Available for backorder

Original price was: € 62.92.Current price is: € 53.48.

Victron Cyrix-ct combiner relay 12/24V-120A – We'd be happy to provide you with more information about this product. Please contact us.

SKU: CYR010120011 Categories: , , Brand: Brand:
CYR010120011

Available for backorder

Victron Cyrix-ct combiner relay 12/24V-120A

Victron Cyrix-ct combiner relay 12/24V-120A Victron Cyrix-ct combiner relay 12/24V-120A Applications For motorhomes, boats, and commercial vehicles where a service battery bank needs to charge along with the starter battery, without the two being connected during discharge. Switches fully automatically based on voltage, without a control panel or control wire. Automatic coupling and disconnection The relay couples both battery banks in parallel as soon as one of the two reaches the coupling voltage and disconnects them again as soon as the voltage drops. The measurement works bidirectionally: it does not matter which battery bank is being charged. * Switch on between 13.0 and 13.8 V, or between 26.0 and 27.6 V * Switch off between 11.0 and 12.8 V, or between 22.0 and 25.7 V * Intelligent trend detection determines the switching time * Switch-on delay of 10 minutes at 13.0 to 13.2 V, decreasing to 4 seconds at 13.6 to 13.8 V * Switch-off delay of 0 seconds to 3 minutes, depending on the voltage Virtually no voltage loss Unlike a diode distributor, this relay switches the battery banks through abruptly. Practically no charging voltage is lost, allowing both battery banks to reach their full charging voltage. Start assist Use the push button to manually connect the battery banks in parallel for 30 seconds. Enough to start the service battery bank even with a dead starter battery. Automatic voltage detection and protection * Automatically detects whether the system is 12 or 24 V * Priority for the starter battery * Overheating protection, switches off at excessive temperature * Operating temperature -40 to +60 °C * Protection class IP54 * M6 terminal bolts Note regarding Euro 5 and Euro 6: Not suitable for Euro 5 and Euro 6 engines with an intelligent alternator. These regulate their charging voltage in such a way that a voltage-controlled relay does not switch reliably. Can be ordered directly with this item: * Red battery cable 25mm² per meter (https://shop.top.systems/default.asp?pageid=88&webgroupfilter=63&artdetail=KABRD0102500) – KABRD0102500 * Crimp cable lug 25mm² > M6 (https://shop.top.systems/default.asp?pageid=88&webgroupfilter=63&artdetail=PSKABOG00025) – PSKABOG00025 * Crimp cable lug 25mm² > M8 (https://shop.top.systems/default.asp?pageid=88&webgroupfilter=63&artdetail=PSKABOG00026) – PSKABOG00026 * MEGA-fuse fuse holder 2xM8 (https://shop.top.systems/default.asp?pageid=88&webgroupfilter=63&artdetail=ZEKHD0000200) – ZEKHD0000200 Related products * TS Mono-stable Relay MSR175A (12/24V) (https://shop.top.systems/default.asp?pageid=88&webgroupfilter=63&artdetail=YTZ069004175) – YTZ069004175 Documentation * Datasheet Cyrix-ct 120A and 230A (EN) (https://www.victronenergy.com/upload/documents/Datasheet-Cyrix-ct-120A-230A-EN.pdf) * Manual Cyrix-ct 120A (NL and EN) (https://www.victronenergy.com/upload/documents/Manual-Cyrix-ct-120-EN-NL-DE-FR-ES.pdf) * Cyrix 120A Dimensions (PDF) (https://www.victronenergy.com/upload/documents/Cyrix-120A.pdf) * Cyrix 120A Dimensions (STEP file) (https://www.victronenergy.com/upload/documents/Cyrix-120A-(step).STEP) * Automotive Certificate ECE R10.6 (https://www.victronenergy.com/upload/documents/Certificate-Automotive-ECE-R10-6-Cyrix-ct-12-24V-120A-&-230A.pdf) * Safety Certificate EN-IEC 60335-1 (https://www.victronenergy.com/upload/documents/Safety-EN-IEC-60335-1-Cyrix.pdf) * Cyrix battery combiner declaration of conformity (https://www.victronenergy.com/upload/documents/Cyrix-Battery-Combiner-2021-12-29.pdf) Videos * Victron Energy webinar: charging via the alternator (EN) (https://www.youtube.com/watch?v=dzU_pQFa19s) Contact Are you unsure whether a voltage-controlled relay fits your alternator, or which fuse and cable cross-section are required? Our specialists would be happy to assist you. Contact us (https://www.top.systems/nl/contact/) for tailored advice. Specifications Continuous current 120 A Peak current 180 A for 5 seconds Nominal voltage 12 and 24 V, automatic detection Switch-on voltage 13.0 to 13.8 V, or 26.0 to 27.6 V Trip-off voltage 11.0 to 12.8 V, or 22.0 to 25.7 V Switch-on delay 10 minutes at 13.0 to 13.2 V, up to 4 seconds at 13.6 to 13.8 V Trip-off delay 0 seconds to 3 minutes, depending on the voltage Start assist Yes, 30 seconds Self-consumption closed 220 mA at 12 V, 120 mA at 24 V Self-consumption open Less than 4 mA Operating temperature -40 to +60 °C Protection class IP54 Connection bolts M6 Dimensions 46 x 46 x 80 mm Weight 0.11 kg EAN 8719076022145 We provide you I would like more information about this product. Please contact us contact join us.
an electric sloop? See our full range.