Victron inverter 12/2k5 230V Smart
Victron Inverter 12/2k5 230V Smart For powering 230V equipment from a 12V battery bank in commercial vehicles, motorhomes, boats, and off-grid applications. The high starting reserve of the toroidal transformer absorbs the starting current of motors, power tools, and LED lighting. The ECO mode limits self-consumption at low or no load, relevant for prolonged standby. Battery voltage Suitable for 12V battery banks with an input range of 9.3-17V. The output delivers 230 VAC pure sine wave, adjustable from 210-245 VAC at 50 Hz or 60 Hz. The shutdown and restart voltage and the pre-alarm are adjustable via VictronConnect. Dynamic shutdown adjusts the shutdown voltage to the load. This is possible for OPzV/OPzS, GEL/AGM, and LiFePO4, but not for a battery bank that also powers other consumers. Continuous output 2400W at 25°C, 2200W at 40°C, and 1500W at 65°C. During a cold start, 2500W is available for 2 hours and 3200W for 15 minutes, with a 4000W peak for 5 seconds. This is the 2500VA model, also known as 12/2500. The no-load consumption is 10W, or 1.3W in ECO mode. Phases Single-phase only. Parallel connection and a 3-phase setup are not supported. Connectability The unit cannot be connected to other inverters. A built-in transfer switch is missing: for automatic switching between shore power or a generator and the inverter, an external automatic transfer switch is required, or you can choose an inverter/charger. Composition Full bridge with toroidal transformer in a steel housing. Short-circuit proof and protected against overload, low and high battery voltage, overheating, AC voltage on the output, and high DC ripple. Construction There is no internal fuse: an external 400A fuse in the positive cable is mandatory. Battery connection with M8 bolts, AC output on screw terminals (L, N, PE). The neutral is connected to the chassis so that a residual current device on the output functions correctly. Protection class IP21, therefore only for a dry room. Mounting Intended for vertical wall mounting. Horizontal mounting is possible, but the unit will cool less effectively. Keep at least 10 cm of clearance all around, place it close to the battery bank but never above it, and use a 1x 95mm² battery cable up to 5 m. A cable length of 5-10 m is not recommended. Tighten battery terminals to a maximum of 11Nm. Communication With the built-in Bluetooth, you configure and read out the device in the VictronConnect app on a smartphone, tablet, or computer. Monitoring in the VRM Portal – Victron Energy (https://vrm.victronenergy.com/login) is possible via the VE.Direct port and a GX device or GlobalLink 520. Remote switching on and off is possible via the remote on/off connector, a BMS, or a GX device. The programmable relay can start a generator, control a fan, or transmit an alarm. Can be ordered directly * Victron Cerbo GX MK2 (https://shop.top.systems/monitoring-control/controlpanelen/victron-cerbo-gx-mk2.html), BPP900450110 * Victron VE.Direct cable 10m (https://shop.top.systems/installation/kabels/communication/victron-ve-direct-kabel-10m.html), ASS030530310 * Victron VE.Direct non-inverting remote on-off cable (https://shop.top.systems/installation/kabels/remote-control/victron-ve-direct-non-inverting-remote-on-off-cable.html), ASS030550320 * Victron VE.Direct to USB interface (https://shop.top.systems/installation/interface/victron-ve-direct-to-usb-interface.html), ASS030530010 Documentation * Datasheet Inverter Smart 2k5 & 4k 230V (NL) (https://www.victronenergy.com/upload/documents/Datasheet-Inverter-Smart-2k5-4k-230V-new-models-NL.pdf) * Datasheet Inverter Smart 2k5 & 4k 230V (EN) (https://www.victronenergy.com/upload/documents/Datasheet-Inverter-Smart-2k5-4k-230V-new-models-EN.pdf) * Manual Inverter Smart 2k5 & 4k 230V online (NL) (https://www.victronenergy.com/media/pg/Inverter_Smart_2k5_&_4k_230V_-_new_models/nl/index-nl.html) * Manual Inverter Smart 2k5 & 4k 230V online (EN) (https://www.victronenergy.com/media/pg/Inverter_Smart_2k5_&_4k_230V_-_new_models/en/index-en.html) * Manual Inverter Smart 2k5 & 4k 230V PDF (EN) (https://www.victronenergy.com/upload/documents/Inverter_Smart_2k5_&_4k_230V_-_new_models/106668-Inverter_VE_Direct__Smart_and_SUN-pdf-en.pdf) * Connection overview and dimensions 2k5 (EN) (https://www.victronenergy.com/media/pg/Inverter_Smart_2k5_&_4k_230V_-_new_models/en/appendix.html) * Manual VictronConnect app (EN) (https://www.victronenergy.com/media/pg/VictronConnect_app/en/index-en.html) * Victron Energy ISO 9001 certificate (EN) (https://www.victronenergy.com/upload/documents/ISO9001-certificate-2024-EN.pdf) Videos * Did You Know – Reduce power consumption of an inverter in standby (https://www.youtube.com/watch?v=v0s0x0hf66I) * VictronConnect (https://www.victronenergy.com/upload/documents/Promo%20videos/Product%20video's/VictronConnect/16×9/EN_VictronConnect.mp4) Q&A Can you connect multiple devices in parallel or in 3-phase? No, parallel connection and a 3-phase setup are not supported. Which fuse and battery cable are required? An external 400A fuse and 1x 95mm² battery cable up to 5 m. There is no internal fuse; a cable length of 5-10 m is not recommended. Does a residual current device operate on the AC output? Yes, the neutral is connected to the chassis so that a residual current device functions correctly. For a floating neutral, that connection must be removed. How much power does the inverter consume without load? 10W in normal operation and 1.3W in ECO mode. The on/off level of ECO mode is adjustable in VictronConnect. Can the inverter be switched off via a BMS? Yes, via the remote on/off connector. The unit switches on when H is connected to L, H to the battery positive, or L to the battery negative. Is reading data in the VRM Portal possible? Yes, via a VE.Direct cable to a GX device such as the Victron Cerbo GX MK2 (https://shop.top.systems/monitoring-controle/bedieningspanelen/victron-cerbo-gx-mk2.html), BPP900450110, or to a GlobalLink 520. Does the inverter automatically switch to shore power? No, a transfer switch is not built-in. An external automatic transfer switch or an inverter/charger is required for this. Can the inverter be mounted horizontally? Yes, but the unit will cool less effectively. Vertical wall mounting with at least 10 cm of clearance around it is the intended setup. Is 60 Hz or another output voltage adjustable? Yes, the frequency is 50 Hz or 60 Hz and the output voltage is adjustable from 210-245 VAC. Feel free to contact us for advice regarding fuses, cabling, or the connection to your GX device. We are willing to help you think through the entire installation and are happy to answer your question. Contact Top Systems (https://www.top.systems/nl/contact/) Specifications Battery voltage 12V Input voltage range 9.3-17V Continuous power at 25°C 2400W Continuous power at 40°C 2200W Continuous power at 65°C 1500W Time-dependent power (cold start) 2500W for 2 hours, 3200W for 15 minutes Peak power 4000W for 5 seconds Output voltage 230 VAC ±2%, adjustable 210-245 VAC Frequency 50 Hz or 60 Hz ±0.1% Waveform Pure sine wave Maximum efficiency 92% No-load consumption 10W No-load consumption ECO mode 1.3W Parallel and 3-phase No Dynamic shutdown Load-dependent, adjustable Programmable relay DC 4A at 35V or 1A at 60V, AC 4A at 230V Bluetooth Yes VE.Direct port Yes Remote on/off Yes Protections Short circuit, overload, low and high battery voltage, overheating, AC voltage on output, high DC ripple External fuse 400A Battery connection M8 bolts AC connection Screw terminals Operating temperature -40 to +65°C, fan cooling Humidity Max. 95%, non-condensing Housing Steel Protection class IP21 Dimensions (hxwxd) 509 x 219 x 125 mm Weight 13 kg Safety EN-IEC 60335-1 EMCEN 55014-1, EN 55014-2, EN-IEC 61000-6-1, EN-IEC 61000-6-2, EN-IEC 61000-6-3 Automotive ECE R10-5 We would be happy to provide you with more information about this product. Please contact us
contact join us.