Victron inverter RS Smart Solar 48/6000
Victron RS Smart Solar 48/6000 Inverter Combination of pure sine wave inverter and MPPT solar charger in a single housing for off-grid homes, off-grid living, commercial buildings, and 48V drives. The RS 48/6000 converts solar energy from two separate PV fields into charging current and AC voltage; AC-coupled PV inverters on the output contribute to charging via frequency shift. Battery Voltage Suitable for 48V battery banks with a DC input range of 38-62V. The inverter switches off at 37.2V and back on at 43.6V, both adjustable. The output delivers 230 VAC ±2% at 50 Hz ±0.1%, adjustable to 240 VAC and 60 Hz, with a maximum continuous output current of 25A. Power Continuous 4500W at 40°C and 3000W at 65°C; at 25°C 4600W at 46V battery voltage up to 5200W at 52V. Peak power 9000W for 3 seconds or 7000W for 4 minutes. Efficiency 96.5% at 1kW and 94% at 5kW load, no-load consumption 20W. The output is short-circuit protected with a short-circuit current of 45A. Battery charger: Adaptive 3-stage charging algorithm (bulk, absorption, float) with optional equalization. Standard 57.6V absorption and 55.2V float, adjustable within 36-60V. The combined charging current from PV and AC-coupled PV is a maximum of 100A. With the included temperature sensor, the inverter charges with temperature compensation. Full charging via frequency shift is not possible; this stops around 95%. MPPT Two independent trackers of up to 3000W each, totaling 6000W, with MC4 connectors. The PV voltage may not exceed 450V; the MPPT range is 65-450V and the start voltage is 120V. Maximum operating current of 12A and short-circuit current of 16A per tracker. PV and battery are galvanically isolated. A grounded PV field is not permitted. Connectable Up to 12 devices in parallel via VE.Can, or a 3-phase star configuration with a minimum of 3 and a maximum of 12 devices, maximum 4 per phase and evenly distributed. All devices share one battery bank. Delta and split-phase configurations are not possible, nor is combination with a Multi RS. Remote on/off and two programmable inputs control the inverter, for example from a battery management system. Construction Steel housing in IP21, protection class I, with fan cooling and a four-line illuminated display. Protected against short circuit and overload, excessive and insufficient battery voltage, excessive temperature, 230 VAC on the output, and leakage current in the PV field (30mA). The output must never be connected to the grid or a generator. Mounting: Mount vertically on a non-combustible surface with 30 cm of clearance above and below, not directly above lead-acid batteries and not in direct sunlight. Battery cable according to the manual: 35mm² for 0-2 meters with a 125A DC fuse, or 70mm² for 2-5 meters with a 200A DC fuse, per positive and negative terminal. The M8 battery bolts are tightened to a maximum of 14Nm. AC output via screw terminals up to 10mm², with an uninterrupted earth connection; a type A residual current device is permitted. Communication Two VE.Can ports for parallel and 3-phase operation and for connection to a GX device with access to the VRM Portal – Victron Energy (https://vrm.victronenergy.com/login); a GX device only works via VE.Can. The VE.Direct port is for a VE.Direct to USB interface or a GlobalLink 520. Built-in Bluetooth for setup, data reading, and updates using the VictronConnect app on a smartphone. Programmable relay: 4A up to 35 VDC, 1A up to 70 VDC. Packaging In addition to the inverter, a battery temperature sensor is included, to be mounted on the negative terminal of the battery bank. Can be ordered directly with this * Cable set 35mm² 1.5 m red and black M8 (https://shop.top.systems/installatie/kabels/accu/kabelset-35mm-1-5-mtr-rood-en-zwart-m8.html), KABSET010350 – Battery cables (https://shop.top.systems/installatie/kabels/accu/) * Battery cable red 35mm² per meter (https://shop.top.systems/default.asp?pageid=88&webgroupfilter=14&artdetail=KABRD0103500), KABRD0103500 – Battery cables (https://shop.top.systems/installatie/kabels/accu/) * Battery cable black 35mm² per meter (https://shop.top.systems/default.asp?pageid=88&webgroupfilter=14&artdetail=KABZW0103500), KABZW0103500 – Battery cables (https://shop.top.systems/installatie/kabels/accu/) * Red battery cable 70mm² per meter (https://shop.top.systems/installatie/kabels/accu/accukabel-rood-70mm2-per-meter.html), KABRD0107000 – Battery cables (https://shop.top.systems/installatie/kabels/accu/) * LittelFuse fuse 125A MEGA 70V-SF51 (https://shop.top.systems/beveiligen-schakelen/zekeringen/littelfuse-zekering-125a-mega-70v-sf51.html), ZEKLFM070125 – Fuses (https://shop.top.systems/beveiligen-schakelen/zekeringen/) * LittelFuse fuse 200A MEGA 70V-SF51 (https://shop.top.systems/beveiligen-schakelen/zekeringen/littelfuse-zekering-200a-mega-70v-sf51.html), ZEKLFM070200 – Fuses (https://shop.top.systems/beveiligen-schakelen/zekeringen/) * Mega fuse holder M8 35-500A (https://shop.top.systems/beveiligen-schakelen/zekeringhouders/mega-zekeringhouder-m8-35-500a.html), ZEKHD0000805 – Fuse holders (https://shop.top.systems/beveiligen-schakelen/zekeringhouders/) * Victron VE.Direct to USB interface (https://shop.top.systems/installatie/interface/victron-ve-direct-to-usb-interface.html), ASS030530010 – Interface (https://shop.top.systems/installatie/interface/) * Victron Cerbo GX MK2 (https://shop.top.systems/monitoring-controle/bedieningspanelen/victron-cerbo-gx-mk2.html), BPP900450110 – Control panels (https://shop.top.systems/monitoring-controle/bedieningspanelen/) * Victron Ekrano GX (https://shop.top.systems/monitoring-controle/bedieningspanelen/victron-ekrano-gx.html), BPP900480100 – Control panels (https://shop.top.systems/monitoring-controle/bedieningspanelen/) * Communication cable two meters CAT5 U/UTP gray (https://shop.top.systems/installatie/kabels/communicatie/communicatie-kabel-twee-meter-cat5-u-utp-grijs.html), ASS030064951 – Communication cables (https://shop.top.systems/installatie/kabels/communicatie/) * VE.Can RJ45-terminator (2 pcs.) (https://shop.top.systems/installatie/kabels/communicatie/ve-can-rj45-terminator-2-st.html), ASS030700000 – Communication cables (https://shop.top.systems/installatie/kabels/communicatie/) * Red insulation cap 70/95mm² (https://shop.top.systems/default.asp?pageid=88&webgroupfilter=14&artdetail=ISKP232N4V02), ISKP232N4V02 – Insulation caps (https://shop.top.systems/installatie/accessoires-kabels/isolatiekappen/) * Insulation cap black 70/95mm² (https://shop.top.systems/default.asp?pageid=88&webgroupfilter=14&artdetail=ISKP232N4V14), ISKP232N4V14 – Insulation caps (https://shop.top.systems/installatie/accessoires-kabels/isolatiekappen/) Documentation * Manual Inverter RS Smart Solar (NL) (https://www.victronenergy.com/upload/documents/Inverter_RS_Smart_Solar/11676-Inverter_RS_Smart_Solar-pdf-nl.pdf) * Manual Inverter RS Smart Solar (EN) (https://www.victronenergy.com/upload/documents/Inverter_RS_Smart_Solar/11676-Inverter_RS_Smart_Solar-pdf-en.pdf) * Online manual Inverter RS Smart Solar (EN) (https://www.victronenergy.com/media/pg/Inverter_RS_Smart_Solar/en/index-en.html) * Datasheet Inverter RS Smart Solar (NL) (https://www.victronenergy.com/upload/documents/Datasheet-Inverter-RS-Smart-Solar-NL.pdf) * Datasheet Inverter RS Smart Solar (EN) (https://www.victronenergy.com/upload/documents/Datasheet-Inverter-RS-Smart-Solar-EN-.pdf) * Dimensions Inverter RS 48/6000 230V Smart Solar (https://www.victronenergy.com/upload/documents/Inverter-RS-48-6000-230V-Smart-Solar.pdf) * 3D dimensional drawing Inverter RS 48/6000 230V Smart Solar (PDF) (https://www.victronenergy.com/upload/documents/DimensionDrawing-InverterRS-48-6000-230V-Smart-Solar-3D.pdf) * 3D dimension drawing Inverter RS 48/6000 230V Smart Solar (STEP) (https://www.victronenergy.com/upload/documents/DimensionDrawing-InverterRS-48-6000-230V-Smart-Solar.STEP) * EU Declaration of Conformity (RED) (https://www.victronenergy.com/upload/documents/Inverter-RS-48-6000-230V-Smart-Solar-EU-DOC-RED.pdf) * Safety Certificate EN-IEC 62109-1 (https://www.victronenergy.com/upload/documents/Certificate-Safety-EN-IEC-62109-1-Inverter-RS-48-6000-230V-Smart-Solar.pdf) * Safety Certificate IEC 60335-1 (https://www.victronenergy.com/upload/documents/Certificate-Safety-IEC-60335-1-Inverter-RS-48-6000-230V-Smart-Solar.pdf) * VictronConnect app manual (EN) (https://www.victronenergy.com/media/pg/VictronConnect_app/en/index-en.html) Videos * Did You Know – Reduce power consumption of an inverter in standby (EN) (https://www.youtube.com/watch?v=v0s0x0hf66I) * VictronConnect (EN) (https://www.victronenergy.com/upload/documents/Promo%20videos/Product%20video's/VictronConnect/16×9/EN_VictronConnect.mp4) Q&A Can I connect two or more inverters in parallel? Yes, up to 12 devices via VE.Can, with terminators at both ends. Settings must be adjusted per device; VictronConnect does not synchronize them. Can I connect a generator or shore power to the inverter? No, the AC output must never be connected to another AC source. Only grid-following PV inverters are permitted on the output. Can I use existing AC-coupled PV inverters? Yes, via frequency shift they contribute to charging the battery bank, but not fully: charging stops around 95%. The internal MPPT is required for full charging. Which type of residual current protection can I apply to the output? A Type A residual current circuit breaker. The neutral is connected internally to the housing via an earth relay. Can I connect the inverter to a Cerbo GX via VE.Direct? No, a GX device only works via VE.Can. VE.Direct is intended for a GlobalLink 520 or a VE.Direct to USB interface. How much margin should I allow on the PV voltage? Victron recommends a 10% margin on the Voc in cold climates. Exceeding 450V damages the MPPT and is not covered by the warranty. Would you like to know how this inverter fits into your off-grid system, or how best to connect PV fields and the battery bank? Feel free to contact us; we are happy to help you think about the complete installation. Contact Top Systems (https://www.top.systems/nl/contact/). Specifications Battery voltage 48V (DC range 38-62V) Continuous power at 40°C / 65°C 4500W / 3000W Continuous power at 25°C 4600W at 46V, 5200W at 52V Peak power 9000W (3 s), 7000W (4 min) Output voltage 230 VAC ±2%, 50 Hz ±0.1% (adjustable 240 VAC / 60 Hz) Maximum continuous output current 25A MPPT trackers 2 x 3000W, total 6000W Maximum PV voltage 450V MPPT range / start voltage 65-450V / 120V Maximum PV current per tracker 12A (short-circuit current 16A) Maximum charging current 100A (PV and AC-coupled PV combined) Absorption / float 57.6V / 55.2V (adjustable, 36-60V) Low battery voltage off / on 37.2V / 43.6V (adjustable) Efficiency 96.5% at 1kW, 94% at 5kW No-load consumption 20W Parallel / 3-phase Max. 12 devices, max. 4 per phase Communication 2x VE.Can, VE.Direct, Bluetooth Programmable relay 4A up to 35 VDC, 1A up to 70 VDC Programmable inputs 2 (analog/digital) Remote on/off Yes Battery temperature sensor Included Battery connection M8 bolts PV connection MC4 (2x plus, 2x minus) AC connection Screw terminals 10mm² (6 AWG) Operating temperature -40 to +65°C, fan cooling Humidity Max. 95%, non-condensing Maximum altitude 2000 m Housing Steel, IP21, protection class I Dimensions (hxwxd) 425 x 440 x 125 mm Weight 11 kg Safety EN-IEC 60335-1, EN-IEC 60335-2-29, EN-IEC 62109-1, EN-IEC 62109-2 EMCEN 55014-1, EN 55014-2, EN-IEC 61000-3-2, EN-IEC 61000-3-3, IEC 61000-6-1, IEC 61000-6-2, IEC 61000-6-3 We would be happy to provide you with more information about this product. Please contact us
contact join us.