Victron Lynx Power In M10

Available for backorder

Original price was: €181.50.Current price is: €154.28.

Victron Lynx Power In M10 – We'd be happy to provide you with more information about this product. Please contact us.

SKU: LYN020102010 Categories: , , Brand: Brand:
LYN020102010

Available for backorder

Victron Lynx Power In M10

Victron Lynx Power In M10 Applications Suitable for large 12, 24, and 48 V battery banks in yachts, motorhomes, commercial vehicles, and energy storage. Replaces separate busbars with a clear, expandable rail and connects directly to Lynx Distributor, Lynx Shunt VE.Can, and Lynx Smart BMS with M10 rails. Modular DC busbar The housing contains a positive and a negative distribution rail made of tinned copper (8 x 30 mm). Each rail has four M8 terminals for batteries, chargers, or loads, plus a ground connection on the negative rail. Multiple modules can be linked in series to form a single continuous rail with more connection points. 1000 A continuous at 9 to 60 VDC * Nominal current 1000 A continuous, equal to all other Lynx modules * 12 kW at 12 V, 24 kW at 24 V and 48 kW at 48 V system voltage * When combining multiple Lynx modules, the lowest current value in the series applies M10 version: where is the difference M10 refers exclusively to the coupling bolts between the Lynx modules. The connections for cables and fuses are M8 in both versions. M10 modules cannot be coupled directly to M8 modules and vice versa. Fusing This module contains no fuses and no fuse holders. All connected batteries, chargers, and consumers must be externally fused. The sum of all fuse values ​​must not exceed the current value of the Lynx module with the lowest load capacity. If you require fused connections in the rail itself, choose a Lynx Distributor or Lynx Class-T Power In. Installation * Front opens with two screws; red cover on plus, black on minus * M8 cable lugs, with washer, spring washer, and nut in the correct order * Tightening torque M10 torque bolts 33 Nm (17 Nm for serial numbers prior to HQ2340XXXX), M8 nuts 14 Nm * Cable separators hinged or removable; remove the separator pin for cable diameters exceeding 10 mm * Mount in any orientation via 5 mm mounting holes; stickers included for inverted mounting Part of the Lynx distribution system The Lynx distribution system is a modular rail system for DC connections, distribution, fusing, battery monitoring, and lithium battery management. This module is the unfused building block within it and can also be used independently when battery monitoring or management is not required. When used in conjunction with a Lynx Shunt VE.Can or Lynx Smart BMS, always connect the battery bank on the left and the DC system on the right to ensure the state of charge is calculated correctly. Documentation * Lynx Power In M8 and M10 Manual (NL, PDF) (https://www.victronenergy.com/upload/documents/Lynx_Power_In/24532-Lynx_Power_In_Manual-pdf-nl.pdf) * Lynx Power In M8 and M10 Manual (EN, PDF) (https://www.victronenergy.com/upload/documents/Lynx_Power_In/24532-Lynx_Power_In_Manual-pdf-en.pdf) * Lynx Power In M8 and M10 Online Manual (EN, HTML5) (https://www.victronenergy.com/media/pg/Lynx_Power_In/en/index-en.html) * Lynx Power In (M10) Dimensions (PDF) (https://www.victronenergy.com/upload/documents/Lynx-Power-In(M10).pdf) * Lynx Power In 3D Dimensions (M10) (PDF) (https://www.victronenergy.com/upload/documents/Lynx-Power-In(M10)-3D.pdf) * 3D model Lynx Power In (M10) (STEP) (https://www.victronenergy.com/upload/documents/Dimension-Drawing-Lynx-Power-In(M10)-3D.STEP) * CE declaration Lynx DC distribution (PDF) (https://www.victronenergy.com/upload/documents/Lynx-DC-distribution-2023-08-28.pdf) * ISO 9001 certificate Victron Energy (PDF) (https://www.victronenergy.com/upload/documents/ISO9001-certificate-2024-EN.pdf) * Wiring Unlimited, book on cabling and fusing (EN, PDF) (https://www.victronenergy.com/upload/documents/Wiring-Unlimited-EN.pdf) Contact Are you unsure about the structure of your Lynx distribution system, the choice between M8 and M10, or external fuse protection? Our specialists would be happy to calculate your configuration with you and help you think through the complete DC installation. Contact us (https://www.top.systems/nl/contact/). Specifications Voltage range 9 – 60 VDC Nominal current 1000 A continuous Module coupling M10 Cable and fuse connections M8 Connections 4 per rail, plus earth connection Internal fuses None, external fuse protection required Distribution rail material Tinned copper Distribution rail dimensions (hxw) 8 x 30 mm Tightening torque M10 33 Nm (17 Nm for serial number before HQ2340XXXX) Tightening torque M8 14 Nm Housing material ABS Dimensions (hxwxd) 290 x 170 x 80 mm Weight 2.1 kg Protection class IP22 Operating temperature -40 °C to +60 °C Storage temperature -40 °C to +60 °C Humidity Max. 95%, non-condensing Warranty 5 years We would be happy to provide you with more information about this product. Please contact us contact join us.
an electric sloop? See our full range.