Victron Multi RS 48/6000/100-50 230V
Victron Multi RS 48/6000/100-50 230V For energy storage and emergency power in homes, off-grid living, commercial buildings, and drives with a 48V battery bank, where solar power is supplied via a separate MPPT RS or a PV inverter. The 88A charger charges the battery bank from the grid, and with a GX device, the combination operates in a three-phase setup. Also known as Multi RS 48/6k. Battery voltage Suitable for 48V battery banks, with a DC input range of 38V to 62V; the minimum startup voltage is 41V. By default, the inverter switches off at 37.2V and restarts at 43.6V, both adjustable. The output delivers 230 VAC ±2% at 50 Hz ±0.1%, adjustable to 240 VAC and 60 Hz. Nominal power 6000VA, continuous 4500W at 40°C and 3000W at 65°C. Peak power 9kW for 3 seconds and 7kW for 4 minutes from a cold unit; thereafter, the inverter limits to 25A AC. Short-circuit current 45A, maximum output overcurrent protection 30A. No-load power 20W. Efficiency 96.5% at 1kW and 94% at 5kW. Battery charger: Maximum mains charging current 88A at 57.6V. Charging voltages 57.6V absorption and 55.2V trickle, adjustable within 36-60V. A battery temperature sensor is included, and voltage detection compensates for up to 1V loss per cable. The AC input accepts 187-265 VAC at 45-65 Hz. Connectable. Parallel connection is not supported. In three-phase operation, one device operates per phase, with a maximum of three, only in star configuration; combining with an Inverter RS is not possible. An AC-coupled PV inverter up to 5000W on the output is possible, but charges the battery to approximately 95%. Operation and monitoring via a GX device such as the Cerbo GX or Ekrano GX on VE.Can. Construction: Steel housing in blue (RAL 5012), protection class I, fan-cooled; maximum humidity of 95% and altitude of 2000 m. Suitable only for TN and TT grounding systems. Installation: Victron recommends battery cable of 35mm² for up to 2 m with a 125A fuse, or 70mm² for 2 to 5 m with a 200A fuse. Connect the battery to M8 bolts with 14 Nm, and AC cables to screw terminals up to 10mm² with 1.2 Nm. Protect input and output with a circuit breaker of up to 50A. Communication: VE.Can with two RJ45 ports for a GX device, three-phase, the VM-3P75CT and VM-3P5A energy meters, and an MPPT RS; a GX device can only be connected via VE.Can. VE.Direct is exclusively for GlobalLink 520 or the VE.Direct USB interface, Bluetooth for VictronConnect. Monitoring via the VRM Portal – Victron Energy (https://vrm.victronenergy.com/login). Furthermore, a relay (4A up to 35 VDC, 1A up to 70 VDC), two programmable inputs, and remote on/off. General: AC-out-2 is directly connected to the AC input for non-critical loads and cuts out during battery operation; the output is not programmable. ESS is not fully supported in all countries and depends on the grid code; configuration is done in VictronConnect. VE.Configure Assistants and VE.Smart Networking are not supported. Device and battery temperature sensor included. Can be ordered directly * Red battery cable 35mm² per meter (https://shop.top.systems/default.asp?pageid=88&webgroupfilter=16&artdetail=KABRD0103500), KABRD0103500 (category Battery cables (https://shop.top.systems/installatie/kabels/accu/)) * Black battery cable 35mm² per meter (https://shop.top.systems/default.asp?pageid=88&webgroupfilter=16&artdetail=KABZW0103500), KABZW0103500 (category Battery cables (https://shop.top.systems/installatie/kabels/accu/)) * Red battery cable 70mm² per meter (https://shop.top.systems/installatie/kabels/accu/accukabel-rood-70mm-per-meter.html), KABRD0107000 (category Battery cables (https://shop.top.systems/installatie/kabels/accu/)) * Battery cable black 70mm² per meter (https://shop.top.systems/installatie/kabels/accu/accukabel-zwart-70mm-per-meter.html), KABZW0107000 (category Battery cables (https://shop.top.systems/installatie/kabels/accu/)) * LittelFuse fuse 125A MEGA 70V-SF51 (https://shop.top.systems/default.asp?pageid=88&webgroupfilter=16&artdetail=ZEKLFM070125), ZEKLFM070125 (category Fuses (https://shop.top.systems/beveiligen-schakelen/zekeringen/)) * LittelFuse fuse 200A MEGA 70V-SF51 (https://shop.top.systems/beveiligen-schakelen/zekeringen/littelfuse-zekering-200a-mega-70v-sf51.html), ZEKLFM070200 (category Fuses (https://shop.top.systems/beveiligen-schakelen/zekeringen/)) * Mega fuse holder M8 35-300A (https://shop.top.systems/beveiligen-schakelen/zekeringhouders/mega-zekeringhouder-m8-35-300a.html), ZEKHD0000800 (category Fuse holders (https://shop.top.systems/beveiligen-schakelen/zekeringhouders/)) * Victron VE.Direct to USB interface (https://shop.top.systems/installatie/interface/victron-ve-direct-to-usb-interface.html), ASS030530010 (category Interface (https://shop.top.systems/installatie/interface/)) * Victron Cerbo GX MK2 (https://shop.top.systems/monitoring-controle/bedieningspanelen/victron-cerbo-gx-mk2.html), BPP900451100 (category Control panels (https://shop.top.systems/monitoring-controle/bedieningspanelen/)) * Victron Ekrano GX (https://shop.top.systems/monitoring-controle/bedieningspanelen/victron-ekrano-gx.html), BPP900480100 (category Control panels (https://shop.top.systems/monitoring-controle/bedieningspanelen/)) * Victron Energy Meter 3-phase VM-3P75CT (https://shop.top.systems/installatie/energiemeters/victron-energiemeter-3-fase-vm-3p75ct.html), REL200300100 (category Energy meters (https://shop.top.systems/installatie/energiemeters/)) * VE.Can RJ45-terminator (2 pcs.) (https://shop.top.systems/installatie/kabels/communicatie/ve-can-rj45-terminator-2-st.html), ASS030700000 (category Communication cables (https://shop.top.systems/installatie/kabels/communicatie/)) Documentation * Datasheet Multi RS 48/6000 (NL) (https://www.victronenergy.com/upload/documents/Datasheet-Multi-RS-NL.pdf) * Datasheet Multi RS 48/6000 (EN) (https://www.victronenergy.com/upload/documents/Datasheet-Multi-RS-EN.pdf) * Manual Multi RS 230V (NL) (https://www.victronenergy.com/upload/documents/Multi_RS_230V/209435-Multi_RS-pdf-nl.pdf) * Multi RS 230V Manual (EN) (https://www.victronenergy.com/upload/documents/Multi_RS_230V/209435-Multi_RS-pdf-en.pdf) * Multi RS 230V Online Manual (NL) (https://www.victronenergy.com/media/pg/Multi_RS_230V/nl/index-nl.html) * Multi RS 230V Online Manual (EN) (https://www.victronenergy.com/media/pg/Multi_RS_230V/en/index-en.html) * Multi RS 6000/100-50 230V Dimensions (https://www.victronenergy.com/upload/documents/DimensionDrawing-Multi-RS-6000-100-50-230V.pdf) * EU Declaration of Conformity Multi RS (without MPPT) (https://www.victronenergy.com/upload/documents/DoC-Inverter-Multi-RS-non-solar-EU-DOC-RED.pdf) * Victron Energy ISO 9001 Certificate (https://www.victronenergy.com/upload/documents/ISO9001-certificate-2024-EN.pdf) Q&A Can I connect multiple devices in parallel? No, parallel connection is not supported. Three-phase with one device per phase is possible, up to a maximum of three devices. Via which port do I connect a GX device? Exclusively via VE.Can. VE.Direct is intended for GlobalLink 520 or the VE.Direct USB interface. Is ESS fully supported? No, not in all countries; it depends on the grid code. Setup is done in VictronConnect. Can I add an AC-coupled PV inverter? Yes, up to 5000W on the AC output. This charges the battery to approximately 95%. Contact Would you like to know how to set up a three-phase configuration, ESS, or select the right PV strings for your system? Feel free to contact us; we are happy to help you think about your system. Contact Top Systems (https://www.top.systems/nl/contact/). Specifications Battery voltage 48V DC input range 38-62V, start-up from 41V Nominal power 6000VA Continuous power 40 °C / 65 °C 4500W / 3000W Peak power 9kW for 3 s, 7kW for 4 min Maximum inverter current 25A AC Charging current out of AC 88A at 57.6V Charging voltage absorption / trickle 57.6V / 55.2V, adjustable 36-60V Automatic transfer switch 50A AC input 187-265 VAC, 45-65 Hz Output voltage 230 VAC ±2%, 50 Hz ±0.1% Shutdown / restart 37.2V / 43.6V, adjustable Efficiency 96.5% at 1kW, 94% at 5kW No-load power 20W Output short-circuit current 45A Communication VE.Can (2x RJ45), VE.Direct, Bluetooth Programmable relay 4A up to 35 VDC, 1A up to 70 VDC Parallel / three-phase Parallel not supported; three-phase with one device per phase Earthing system TN and TT only Battery temperature sensor Included Battery connection M8 bolts, 14 Nm AC connection Screw terminals 10mm², 1.2 Nm Housing Steel, blue RAL 5012 Dimensions (hxwxd) 462 x 425 x 127 mm Weight 11.2 kg Warranty 5 years EAN 8719076075189 We would be happy to provide you with more information about this product. Please contact us
contact join us.