Victron Multi RS19 Solar 48/6000/100-450/100
Victron Multi RS19 Solar 48/6000/100-450/100 For energy storage with solar panels in homes, off-grid living, commercial buildings, and drives, where the installation is built in a 19-inch cabinet together with rack batteries. The inverter, charger, and two MPPT trackers are housed in a single 3U enclosure, and with a GX device, the combination operates in three-phase or as ESS. Also known as RS19 Solar 48/6k. Battery voltage Suitable for 48V battery banks, with a DC input range of 38V to 62V; the minimum startup voltage is 41V. By default, the inverter shuts off at 37.2V and restarts at 43.6V, both adjustable. The output delivers 230 VAC ±2% at 50 Hz ±0.1%, adjustable to 240 VAC and 60 Hz. Power Nominal 6000VA, continuous 4500W at 40°C and 3000W at 65°C. Peak power 9kW for 3 seconds and 7kW for 4 minutes, from a cold unit; thereafter, the inverter limits to 25A AC. Short-circuit current 45A, maximum output overcurrent protection 30A. No-load power 20W. Battery charger Mains charging current maximum 88A at 57.6V, combined with solar power maximum 100A. Charging voltages 57.6V absorption and 55.2V trickle, adjustable within 36-60V. A battery temperature sensor is included, and voltage detection compensates for up to 1V loss per cable. The AC input accepts 187-265 VAC at 45-65 Hz. MPPT Two independent trackers, combined maximum 6000W and 3000W per tracker. MPPT range 65-450V, startup voltage 120V, maximum open-circuit voltage 450V, and always lower than 8 times the battery trickle voltage. Maximum input current 12A and short-circuit current 16A per tracker. Connect a separate PV field per tracker; the RCD monitoring on the PV input trips at 30 mA. Connectable. Parallel connection is not supported. In three-phase, one device operates per phase, maximum three, only in star configuration; combining with an Inverter RS is not possible. An AC-coupled PV inverter up to 5000W on the output is possible, but charges the battery to approximately 95%. Operation and monitoring via a GX device such as the Cerbo GX or Ekrano GX on VE.Can. Construction: 19-inch 3U steel housing in blue (RAL 5012), protection degree IP20, protection class I, fan-cooled. Operating temperature -40 to +65 °C, maximum 95% humidity, and 2000 m altitude. Only suitable for TN and TT grounding systems. Mounting: Place the housing horizontally in a 19-inch cabinet with at least 1U of clearance above and below and airflow from front to back. Connect the battery using Amphenol SurLok Plus 5.7 mm plugs (120A, 25mm²); Victron recommends 25mm² battery cable up to 2 m with a 125A fuse. The AC connection is made using spring clips. Protect the input and output with a circuit breaker of maximum 50A. Communication: VE.Can with two RJ45 ports for a GX device, three-phase, the energy meters VM-3P75CT and VM-3P5A, and an MPPT RS; a GX device can only be connected via VE.Can. VE.Direct is exclusively for GlobalLink 520 or the VE.Direct USB interface; Bluetooth is for VictronConnect. The additional BMS CAN port is intended only for small, single-unit systems without a GX device or DVCC. Monitoring is via the VRM Portal – Victron Energy (https://vrm.victronenergy.com/login). Furthermore, it features a relay (4A up to 35 VDC, 1A up to 70 VDC), two programmable inputs, and remote on/off. General AC-out-2 is directly connected to the AC input for non-critical loads and cuts out during battery operation; the output is not programmable. ESS is not fully supported in all countries and depends on the grid code; configuration is done in VictronConnect. VE.Configure Assistants and VE.Smart Networking are not supported. Without a battery, the unit operates as a PV grid inverter. Included: Unit and battery temperature sensor. Can be ordered directly with this * Red battery cable 25mm² per meter (https://shop.top.systems/default.asp?pageid=88&webgroupfilter=16&artdetail=KABRD0102500), KABRD0102500 (category Battery cables (https://shop.top.systems/installatie/kabels/accu/)) * Black battery cable 25mm² per meter (https://shop.top.systems/default.asp?pageid=88&webgroupfilter=16&artdetail=KABZW0102500), KABZW0102500 (category Battery cables (https://shop.top.systems/installatie/kabels/accu/)) * LittelFuse fuse 125A MEGA 70V-SF51 (https://shop.top.systems/default.asp?pageid=88&webgroupfilter=16&artdetail=ZEKLFM070125), ZEKLFM070125 (category Fuses (https://shop.top.systems/beveiligen-schakelen/zekeringen/)) * Mega fuse holder M8 35-300A (https://shop.top.systems/beveiligen-schakelen/zekeringhouders/mega-zekeringhouder-m8-35-300a.html), ZEKHD0000800 (category Fuse holders (https://shop.top.systems/beveiligen-schakelen/zekeringhouders/)) * Victron VE.Direct to USB interface (https://shop.top.systems/installatie/interface/victron-ve-direct-to-usb-interface.html), ASS030530010 (category Interface (https://shop.top.systems/installatie/interface/)) * Victron Cerbo GX MK2 (https://shop.top.systems/monitoring-controle/bedieningspanelen/victron-cerbo-gx-mk2.html), BPP900451100 (category Control panels (https://shop.top.systems/monitoring-controle/bedieningspanelen/)) * Victron Ekrano GX (https://shop.top.systems/monitoring-controle/bedieningspanelen/victron-ekrano-gx.html), BPP900480100 (category Control panels (https://shop.top.systems/monitoring-controle/bedieningspanelen/)) * Victron Energy meter 3-phase VM-3P75CT (https://shop.top.systems/installatie/energiemeters/victron-energiemeter-3-fase-vm-3p75ct.html), REL200300100 (category Energy meters (https://shop.top.systems/installatie/energiemeters/)) * VE.Can RJ45 terminator (2 pcs.) (https://shop.top.systems/installatie/kabels/communicatie/ve-can-rj45-terminator-2-st.html), ASS030700000 (category Communication cables (https://shop.top.systems/installatie/kabels/communicatie/)) * Solar cable 6mm² 5 meters MC4 male/female (https://shop.top.systems/default.asp?pageid=88&webgroupfilter=16&artdetail=SCA000500100), SCA000500100 (category Solar panel accessories (https://shop.top.systems/zonnestroom/accessoires-zonnepanelen/)) Documentation * Datasheet Multi RS19 Solar (NL) (https://www.victronenergy.com/upload/documents/Datasheet-Multi-RS19-Solar-NL.pdf) * Datasheet Multi RS19 Solar (EN) (https://www.victronenergy.com/upload/documents/Datasheet-Multi-RS19-Solar-EN.pdf) * Multi RS19 Solar Manual (NL) (https://www.victronenergy.com/upload/documents/Multi_RS19_Solar/157372-Multi_RS19_Solar-pdf-nl.pdf) * Multi RS19 Solar Manual (EN) (https://www.victronenergy.com/upload/documents/Multi_RS19_Solar/157372-Multi_RS19_Solar-pdf-en.pdf) * Multi RS19 Solar Online Manual (NL) (https://www.victronenergy.com/media/pg/Multi_RS19_Solar/nl/index-nl.html) * Multi RS19 Solar Online Manual (EN) (https://www.victronenergy.com/media/pg/Multi_RS19_Solar/en/index-en.html) * Dimensions Multi RS19 Solar 48/6000/100-450/100 (https://www.victronenergy.com/upload/documents/DimensionDrawing-Multi-RS19-Solar-48V6000VA-100-450-100-(PMR482602030).pdf) * Certificate IEC 62109-1 / 62109-2 Multi RS19 Solar (https://www.victronenergy.com/upload/documents/Certificate-IEC-62109-1-62109-2-Multi-RS19-Solar.pdf) * Certificate IEC 60335-1 / 60335-2 Multi RS19 Solar (https://www.victronenergy.com/upload/documents/Certificate-IEC-60335-1-60335-2-Multi-RS19-Solar.pdf) * Certificate EN 50549-1 / 50549-10 Multi RS19 Solar (https://www.victronenergy.com/upload/documents/Certificate-ESS-EN-50549-1-10-Multi-RS19-Solar.pdf) * ISO 9001 certificate Victron Energy (https://www.victronenergy.com/upload/documents/ISO9001-certificate-2024-EN.pdf) Q&A Can I connect multiple devices in parallel? No, parallel connection is not supported. Three-phase with one device per phase is possible, up to a maximum of three devices. Via which port do I connect a GX device? Exclusively via VE.Can. VE.Direct is intended for GlobalLink 520 or the VE.Direct USB interface. How many solar panels can I connect? 3000W per tracker, 6000W total, with a maximum open-circuit voltage of 450V and lower than 8 times the trickle voltage. Does the device work without a battery? Yes, as a PV grid inverter with a configured grid code. A 48V battery bank is required for emergency power and storage. Is ESS fully supported? No, not in all countries; it depends on the grid code. Configuration is done in VictronConnect. Can I add an AC-coupled PV inverter? Yes, up to 5000W on the AC output. This charges the battery to approximately 95%. What is the purpose of the BMS CAN port? Only for small single-device systems without a GX device. You connect the battery BMS to the GX using a GX device. Contact Do you want to know how to set up a three-phase configuration, ESS, or select the right PV strings for your system? Feel free to contact us; we are happy to help you think about your system. Contact Top Systems (https://www.top.systems/nl/contact/). Specifications Battery voltage 48V DC input range 38-62V, startup from 41V Nominal power 6000VA Continuous power 40 °C / 65 °C 4500W / 3000W Peak power 9kW for 3 s, 7kW for 4 min Maximum inverter current 25A AC Charging current out of AC 88A at 57.6V Charging current AC and PV combined 100A Charging voltage absorption / trickle 57.6V / 55.2V, adjustable 36-60V Automatic transfer switch 50A AC input 187-265 VAC, 45-65 Hz Output voltage 230 VAC ±2%, 50 Hz ±0.1% Shutdown / restart 37.2V / 43.6V, adjustable Number of MPPT trackers 2 Maximum PV power 6000W total, 3000W per tracker MPPT range / Startup voltage 65-450V / 120V Maximum PV open-circuit voltage 450V PV current / short-circuit current 12A / 16A per tracker Open-circuit power 20W Output short-circuit current 45A Communication VE.Can (2x RJ45), VE.Direct, BMS-Can, Bluetooth Programmable relay 4A up to 35 VDC, 1A up to 70 VDC Parallel / three-phase Parallel not supported; Three-phase with one device per phase Earthing system: TN and TT only Battery temperature sensor: Included Battery connection: Amphenol SurLok Plus 5.7 mm, 120A AC connection Spring clamps Housing: Steel, 19 inch, 3U, blue RAL 5012 Protection degree: IP20, protection class I Operating temperature: -40 to +65 °C Dimensions (hxwxd): 133 x 483 x 430 mm Weight: 12.2 kg Standards: IEC 62109-1, IEC 62109-2, IEC 60335-1, EN 50549-1, EN 50549-10 Warranty: 5 years EAN: 8719076058403 We would be happy to provide you with more information about this product. Please contact us
contact join us.