Victron MultiPlus-II 48/15000/200-100
Victron MultiPlus-II 48/15000/200-100 For homes, off-grid living, commercial buildings, and drives with a large 48V battery bank and a continuous consumption of up to 12,000W, such as a commercial building with machinery, an off-grid farm, or a charging plaza. With a GX device, the combination operates as an ESS, and the 200A charger quickly recharges the battery bank. Also known as 48/15k; in three-phase with one device per phase. Battery voltage Suitable for 48V battery banks, with a DC input range of 38-66V. The AC input accepts 187-265 VAC at 45-65 Hz; the output delivers 230 VAC ±2% at 50 Hz ±0.1%, switchable to 60 Hz. Power Nominal 15,000VA. Continuous 12000W at 25°C, 10000W at 40°C, and 7000W at 65°C. Peak power 27000W. No-load power 55W, 39W in AES mode, and 6W in search mode. The automatic transfer switch handles a maximum of 100A; with PowerControl and PowerAssist, the combination limits the input current and supplements any deficit from the battery. Battery charger. Charging current 200A. Adaptive four-phase charger with bulk, absorption, trickle, and storage (BatterySafe). Charging voltages 57.6V absorption, 55.2V trickle. Voltage detection compensates for voltage loss across the battery cables. Connectable. Three-phase is possible with one device per phase; parallel connection per phase is only possible in the External Transfer Switch application. In this configuration, you connect only the master per phase to AC-in, using firmware with the S99 option and a GX device with Venus OS 3.33 or higher. Use one remote control per system. Operation and readout via a Digital Multi Control, the VE.Bus Smart dongle, or a GX device such as the Cerbo GX. Construction: Steel housing in blue (RAL 5012), fan-cooled, operating temperature -40 to +65 °C. Protected against short circuit, overload, over- and under-battery voltage, over-temperature, 230 VAC on the inverter output, and excessive ripple voltage on the input. Mounting: Victron recommends a 600A DC fuse and battery cable of 2x 95mm² for cable lengths up to 5 m, or 2x 150mm² for lengths from 5 to 10 m; copper cable suitable for 90 °C. Connect the battery using 4x M8 bolts, with 12 Nm. Connect the AC cables to M6 bolts. A Type A RCD is permitted on the output. Communication via VE.Bus with two RJ45 ports; no VE.Can or BMS-Can. Configuration using VEConfigure or VictronConnect via an MK3 USB interface or the VE.Bus Smart dongle. A GX device is required for monitoring via the VRM Portal – Victron Energy (https://vrm.victronenergy.com/login) and for ESS. Furthermore, two programmable auxiliary inputs, voltage detection, and remote on/off. General AC-out-1 is continuous: in the event of a mains failure, the inverter takes over the power supply within 20 ms. AC-out-2 is a 50A auxiliary output that switches off during battery operation and switches back on after the return of mains voltage, for example for a water heater. With a GX device suitable for ESS; The device is listed on the Victron certificates EN 50549-1 and IEC 62116 (single-phase). Can be ordered directly * Red battery cable 95mm² per meter (https://shop.top.systems/installatie/kabels/accu/accukabel-rood-95mm-per-meter.html), KABRD0109500 (category Battery cables (https://shop.top.systems/installatie/kabels/accu/)) * Black battery cable 95mm² per meter (https://shop.top.systems/installatie/kabels/accu/accukabel-zwart-95mm-per-meter.html), KABZW0109500 (category Battery cables (https://shop.top.systems/installatie/kabels/accu/)) * Crimp cable lug 95mm² > M8 (https://shop.top.systems/installatie/accessoires-kabels/perskabelogen/perskabeloog-95mm-m8.html), PSKABOG00094 (category Crimp cable lugs (https://shop.top.systems/installation/accessories-cables/press-cable-eyes/)) * Victron VE.Bus Smart dongle (https://shop.top.systems/default.asp?pageid=88&webgroupfilter=16&artdetail=ASS030537010), ASS030537010 * Victron Digital Multi Control 200/200A (https://shop.top.systems/monitoring-control/controlpanels/victron-digital-multi-control-200-200a.html), REC020005010 (category Control panels (https://shop.top.systems/monitoring-control/controlpanels/)) * Victron Digital Multi Control 200/200A GX (90º) (https://shop.top.systems/monitoring-controle/bedieningspanelen/victron-digital-multi-control-200-200a-gx-90.html), DMC000200010R (category Control panels (https://shop.top.systems/monitoring-controle/bedieningspanelen/)) * Victron Cerbo GX MK2 (https://shop.top.systems/monitoring-controle/bedieningspanelen/victron-cerbo-gx-mk2.html), BPP900451100 (category Control panels (https://shop.top.systems/monitoring-controle/bedieningspanelen/)) Related products * Victron MultiPlus-II 48/10000/140-100 (https://shop.top.systems/omvormen-laden/omvormen-laden-combi/victron-multiplus-ii-48-10000-140-100.html), PMP483105000 Documentation * Datasheet MultiPlus-II inverter/charger 230V (NL) (https://www.victronenergy.com/upload/documents/Datasheet-MultiPlus-II-inverter-charger-NL.pdf) * Datasheet MultiPlus-II 3kVA – 15kVA 230V (EN) (https://www.victronenergy.com/upload/documents/Datasheet-MultiPlus-II-inverter-charger-EN-.pdf) * Manual MultiPlus-II 230V (NL) (https://www.victronenergy.com/upload/documents/MultiPlus-II_230V/32424-MultiPlus-II___Quattro-II-pdf-nl.pdf) * Manual MultiPlus-II 230V (EN) (https://www.victronenergy.com/upload/documents/MultiPlus-II_230V/32424-MultiPlus-II___Quattro-II-pdf-en.pdf) * Online manual MultiPlus-II 230V (NL) (https://www.victronenergy.com/media/pg/MultiPlus-II_230V/nl/index-nl.html) * Online manual MultiPlus-II 230V (EN) (https://www.victronenergy.com/media/pg/MultiPlus-II_230V/en/index-en.html) * Online manual External Transfer Switch application (EN) (https://www.victronenergy.com/media/pg/MultiPlus-II_External_Transfer_Switch_application/en/index-en.html) * Manual External Transfer Switch application (EN) (https://www.victronenergy.com/upload/documents/MultiPlus-II_External_Transfer_Switch_application/179843-MultiPlus-II_external_transfer_switch_application-pdf-en.pdf) * Online manual ESS Design and Installation (EN) (https://www.victronenergy.com/media/pg/Energy_Storage_System/en/index-en.html) * VE.Bus parallel, split and three-phase systems (EN) (https://www.victronenergy.com/live/ve.bus:manual_parallel_and_three_phase_systems) * VE.Bus error codes (EN) (https://www.victronenergy.com/live/ve.bus:ve.bus_error_codes) * EU Declaration of Conformity MultiPlus-II (https://www.victronenergy.com/upload/documents/DoC-MultiPlus-II-(EU)-0226.pdf) * Certificate EN-IEC 62109-1 and 2 all MultiPlus-II (GX) (https://www.victronenergy.com/upload/documents/Certificate-EN-IEC-62109-1-2-all-MultiPlus-II-(GX).pdf) * Certificate EN 50549-1 MultiPlus-II 48V 8kVA, 10kVA and 15kVA (https://www.victronenergy.com/upload/documents/Certificate-ESS-EN-50549-1-MultiPlus-II-48V-8kVA-48V-10kVA-48V-15kVA-2026.pdf) * Certificate IEC 62116 MultiPlus-II single-phase 48V 8kVA, 10kVA and 15kVA (https://www.victronenergy.com/upload/documents/Certificate-ESS-IEC-62116-MultiPlus-II-Single-Phase-48V-8kVA,-10kVA-15kVA-2026.pdf) * Certificate IEC 60335-1 / 60335-2 MultiPlus-II (GX) 3kVA to 15kVA (https://www.victronenergy.com/upload/documents/Certificate-IEC-60335-1-60335-2-MultiPlus-II-(GX)-3kVA,-5kVA,-8kVA,-10kVA-&-15kVA.pdf) * Dimensions MultiPlus-II 48V 15kVA (https://www.victronenergy.com/upload/documents/DimensionDrawing-48V15kVA-MultiPlus-II.pdf) * Victron Energy ISO 9001 Certificate (https://www.victronenergy.com/upload/documents/ISO9001-certificate-2024-EN.pdf) Videos * Introduction: MultiPlus-II (EN) (https://www.youtube.com/watch?v=nU5yUY6VhIU) * Did You Know – You can update a MultiPlus Firmware using an Android Phone? (EN) (https://youtu.be/AEPmjkyg7UY) Question & Answer Why does AC-out-2 switch off when running on battery power? It is designed this way: AC-out-2 switches off during battery operation and switches back on after the return of mains voltage. Connect consumers to it that are allowed to switch off in the event of a power outage. Can I connect devices in parallel or in three-phase? Three-phase is possible with one device per phase. Parallel connection per phase is only possible in the External Transfer Switch application, with an external transfer switch, firmware with the S99 option, a GX device with Venus OS 3.33 or higher, and only the master per phase on AC-in. Which RCD is allowed on the output? Type A is permitted. The built-in earth relay connects neutral and earth in inverter operation. What settings do I configure for an inverter unit or low shore power? Use PowerControl and PowerAssist with AC input current limiting and switch on the dynamic current limiter for an inverter unit; WeakAC is for distorted grid voltage. Can I use this device for ESS with grid feed-in? Yes, with a GX device. This model is listed on the Victron certificates EN 50549-1 and IEC 62116 for single-phase; you select the grid code in VEConfigure. Contact Do you want to know which cable, fuse, or GX device belongs to your installation, or how to connect multiple devices? Feel free to contact us; we are happy to help you think about your system. Contact Top Systems (https://www.top.systems/nl/contact/). Specifications Battery voltage 48V DC input range 38-66V Nominal power 15000VA Continuous power 25/40/65 °C 12000W / 10000W / 7000W Peak power 27000W Charging current 200A Charging voltage absorption/trickle 57.6V / 55.2V Automatic transfer switch 100A No-load power / AES / search mode 55W / 39W / 6W AC input 187-265 VAC, 45-65 Hz Output voltage 230 VAC ±2%, 50 Hz ±0.1% AC output -250A, mains voltage only PowerControl / PowerAssist Yes / Yes Communication VE.Bus, 2x RJ45 Parallel / three-phase Parallel only with external transfer switch; Three-phase with one device per phase Recommended DC fuse 600A Battery cable 0-5 m / 5-10 m 2x 95mm² / 2x 150mm² Battery connection 4x M8 bolts, 12 Nm Housing Steel, blue RAL 5012 Operating temperature -40 to +65 °C, fan-cooled Dimensions (hxwxd) 810 x 405 x 217 mm Weight 80 kg Warranty 5 years EAN 8719076056324 We would be happy to provide you with more information about this product. Please contact us
contact join us.