Victron MultiPlus-II 48/3000/35-32

Available for backorder

Original price was: € 755.04.Current price is: € 641.78.

Victron MultiPlus-II 48/3000/35-32 – We would be happy to provide you with more information about this product. Please contact us.

PMP482305012

Available for backorder

Victron MultiPlus-II 48/3000/35-32

Victron MultiPlus-II 48/3000/35-32 For energy storage and emergency power in homes, off-grid living, commercial buildings, and drives with a 48V battery bank. With a GX device, the combination functions as an ESS: storing solar power, increasing self-consumption, and taking over power within 20 ms in the event of a grid failure. Also known as 48/3k; expandable to a three-phase system. Battery voltage Suitable for 48V battery banks, with a DC input range of 38-66V. The AC input accepts 187-265 VAC at 45-65 Hz; the output delivers 230 VAC ±2% ​​at 50 Hz ±0.1%, switchable to 60 Hz. Power Continuous 2400W at 25 °C, 2200W at 40 °C, and 1700W at 65 °C; Nominal 3000VA at crest factor 3:1. Peak power 5500W. Maximum efficiency 95%. No-load power 11W, 7W in AES mode, and 2W in search mode. The automatic transfer switch handles a maximum of 32A; with PowerControl and PowerAssist, the combination limits the input current and supplements any deficit from the battery. Battery charger: Charging current 35A down to 25°C. Adaptive four-phase charger with bulk, absorption, trickle, and storage (BatterySafe), absorption duration up to 8 hours and repeated absorption of 1 hour once every 7 days. Charging voltages 57.6V absorption, 55.2V trickle, and 52.8V storage. Voltage detection compensates for up to 1V loss per cable. Connectable: Up to six identical devices in parallel on the same battery, using DC cables of equal length and cross-section and UTP cables directly from device to device. Three-phase only in star configuration, not in delta. Use one remote control per system. Operation and readout via a Digital Multi Control, the VE.Bus Smart dongle, or a GX device such as the Cerbo GX. Construction Steel housing in blue (RAL 5012), protection class IP22, fan-cooled, operating temperature -40 to +65 °C. Protected against short circuit, overload, over- and under-battery voltage, over-temperature, 230 VAC on the inverter output, and excessive ripple voltage on the input. Installation Victron recommends a 125A DC fuse and 35mm² battery cable for cable lengths up to 5 m, or 70mm² for 5 to 10 m; copper cable suitable for 90 °C, not in a closed conduit. Connect the battery to M8 bolts with 12 Nm. Protect the AC input with a fuse or circuit breaker of maximum 32A. AC connection on screw terminals of maximum 13mm²; earth on M6 with 5.5 Nm. A type A RCD is permitted on the output. Communication VE.Bus with two RJ45 ports; no VE.Can or BMS-Can. Configuration with VEConfigure or VictronConnect via an MK3 USB interface or the VE.Bus Smart dongle. A GX device is required for monitoring via the VRM Portal – Victron Energy (https://vrm.victronenergy.com/login) and for ESS. Furthermore, two programmable auxiliary inputs, a programmable relay (4A up to 35 VDC, 1A up to 60 VDC), an open-collector output, and remote on/off. General AC-out-1 is uninterruptible: in the event of a power outage, the inverter takes over the power supply within 20 ms. AC-out-2 is an auxiliary output that switches off during battery operation and switches back on approximately 2 minutes after the return of mains power, for example for a water heater. The unit is listed on Victron certificates EN 50549-1 and IEC 62116 for mains connection. Can be ordered directly * Red battery cable 35mm² per meter (https://shop.top.systems/default.asp?pageid=88&webgroupfilter=16&artdetail=KABRD0103500), KABRD0103500 (category Battery cables (https://shop.top.systems/installatie/kabels/accu/)) * Black battery cable 35mm² per meter (https://shop.top.systems/default.asp?pageid=88&webgroupfilter=16&artdetail=KABZW0103500), KABZW0103500 (category Battery cables (https://shop.top.systems/installatie/kabels/accu/)) * Crimp cable lug 35mm² > M8 (https://shop.top.systems/default.asp?pageid=88&webgroupfilter=16&artdetail=PSKABOG00036), PSKABOG00036 (category Crimp lugs (https://shop.top.systems/installatie/accessoires-kabels/perskabelogen/)) * Cable set 35mm² 1.5 m red and black M8-M8 (https://shop.top.systems/default.asp?pageid=88&webgroupfilter=16&artdetail=KABSET010351), KABSET010351 (category Battery cables (https://shop.top.systems/installatie/kabels/accu/)) * LittelFuse fuse 125A MEGA 70V-SF51 (https://shop.top.systems/default.asp?pageid=88&webgroupfilter=16&artdetail=ZEKLFM070125), ZEKLFM070125 (category Fuses (https://shop.top.systems/beveiligen-schakelen/zekeringen/)) * Mega fuse holder M8 35-300A (https://shop.top.systems/default.asp?pageid=88&webgroupfilter=16&artdetail=ZEKHD0000800), ZEKHD0000800 (category Fuse holders (https://shop.top.systems/beveiligen-schakelen/zekeringhouders/)) * Victron VE.Bus Smart dongle (https://shop.top.systems/default.asp?pageid=88&webgroupfilter=16&artdetail=ASS030537010), ASS030537010 * Victron Digital Multi Control 200/200A (https://shop.top.systems/monitoring-control/controlpanels/victron-digital-multi-control-200-200a.html), REC020005010 (category Control panels (https://shop.top.systems/monitoring-control/controlpanels/)) * Victron Digital Multi Control 200/200A GX (90º) (https://shop.top.systems/monitoring-control/controlpanels/victron-digital-multi-control-200-200a-gx-90.html), DMC000200010R (category Control panels (https://shop.top.systems/monitoring-control/controlpanels/)) * Victron Cerbo GX MK2 (https://shop.top.systems/monitoring-controle/bedieningspanelen/victron-cerbo-gx-mk2.html), BPP900451100 (category Control panels (https://shop.top.systems/monitoring-controle/bedieningspanelen/)) Related products * Victron MultiPlus-II 48/4k5/55-32 230V (https://shop.top.systems/omvormen-laden/omvormen-laden-combi/victron-multiplus-ii-48-4k5-55-32-230v.html), PMP482405012 * Victron MultiPlus-II 48/5000/70-50 230V (https://shop.top.systems/omvormen-laden/omvormen-laden-combi/victron-multiplus-ii-48-5000-70-50-230v.html), PMP482505012 * Victron MultiPlus-II 48/6k5/100-50 230V (https://shop.top.systems/omvorm-laden/omvorm-laden-combi/victron-multiplus-ii-48-6k5-100-50-230v.html), PMP482605012 * Victron MultiPlus-II 48/8000/110-100 (https://shop.top.systems/omvorm-laden/omvorm-laden-combi/victron-multiplus-ii-48-8000-110-100.html), PMP482805000 * Victron MultiPlus-II 48/10000/140-100 (https://shop.top.systems/omvormen-laden/omvormen-laden-combi/victron-multiplus-ii-48-10000-140-100.html), PMP483105000 Documentation * Datasheet MultiPlus-II inverter/charger 230V (NL) (https://www.victronenergy.com/upload/documents/Datasheet-MultiPlus-II-inverter-charger-NL.pdf) * Datasheet MultiPlus-II 3kVA – 15kVA 230V (EN) (https://www.victronenergy.com/upload/documents/Datasheet-MultiPlus-II-inverter-charger-EN-.pdf) * Manual MultiPlus-II 230V (NL) (https://www.victronenergy.com/upload/documents/MultiPlus-II_230V/32424-MultiPlus-II___Quattro-II-pdf-nl.pdf) * Manual MultiPlus-II 230V (EN) (https://www.victronenergy.com/upload/documents/MultiPlus-II_230V/32424-MultiPlus-II___Quattro-II-pdf-en.pdf) * Online manual MultiPlus-II 230V (NL) (https://www.victronenergy.com/media/pg/MultiPlus-II_230V/nl/index-nl.html) * Online manual MultiPlus-II 230V (EN) (https://www.victronenergy.com/media/pg/MultiPlus-II_230V/en/index-en.html) * Quick Install Guide MultiPlus-II 24V/48V 3kVA and 48V 5kVA 230Vac (EN) (https://www.victronenergy.com/upload/documents/Quick-Install-Guide-MultiPlus-II-24V48V-3000VA-48V-5000VA-230Vac-EN.pdf) * Quick Install Guide MultiPlus-II 48V 3000VA 230Vac (EN) (https://www.victronenergy.com/upload/documents/Quick-Install-Guide-MultiPlus-II-48V-3000VA-230Vac-EN.pdf) * Online manual ESS Design and Installation (EN) (https://www.victronenergy.com/media/pg/Energy_Storage_System/en/index-en.html) * VE.Bus parallel, split and three-phase systems (EN) (https://www.victronenergy.com/live/ve.bus:manual_parallel_and_three_phase_systems) * VE.Bus error codes (EN) (https://www.victronenergy.com/live/ve.bus:ve.bus_error_codes) * EU Declaration of Conformity MultiPlus-II (https://www.victronenergy.com/upload/documents/DoC-MultiPlus-II-(EU)-0226.pdf) * Certificate IEC 60335-1 / 60335-2 MultiPlus-II (GX) 3kVA to 15kVA (https://www.victronenergy.com/upload/documents/Certificate-IEC-60335-1-60335-2-MultiPlus-II-(GX)-3kVA,-5kVA,-8kVA,-10kVA-&-15kVA.pdf) * Certificate EN-IEC 62109-1 and 2 all MultiPlus-II (GX) (https://www.victronenergy.com/upload/documents/Certificate-EN-IEC-62109-1-2-all-MultiPlus-II-(GX).pdf) * Certificate IEC 62116 all MultiPlus-II and MultiPlus-II GX (https://www.victronenergy.com/upload/documents/Certificate-ESS-IEC-62116-all-MultiPlus-II-and-MultiPlus-II-GX.pdf) * Certificate EN 50549-1 MultiPlus-II (GX) 3k and 5k (https://www.victronenergy.com/upload/documents/Certificate-ESS-EN-50549-1-all-MultiPlus-II-(GX)-3k-&-5k.pdf) * Certificate EN 50549-1 and EN 50549-10 MultiPlus-II (GX) 24V 3k, 48V 3k, 4k5, 5k, 6k5 (https://www.victronenergy.com/upload/documents/Certificate-ESS-EN-50549-1-EN-50549-10-MultiPlus-II-(GX)-24V-3kV-48V-3kV-4,5kV-5kV-6.5kV.pdf) * Dimensions MultiPlus-II 48V 3000VA 230V PMP482305012 (https://www.victronenergy.com/upload/documents/MultiPlus-II-48V-3000VA-230V-PMP482305012.pdf) * ISO 9001 certificate Victron Energy (https://www.victronenergy.com/upload/documents/ISO9001-certificate-2024-EN.pdf) Videos * Introduction: MultiPlus-II (EN) (https://www.youtube.com/watch?v=nU5yUY6VhIU) * Did You Know – You can update a MultiPlus Firmware using an Android Phone? (EN) (https://youtu.be/AEPmjkyg7UY) Question & Answer Why does AC-out-2 trip on battery power? It is designed this way: AC-out-2 switches off immediately during battery operation and switches back on approximately 2 minutes after the return of mains power. Can I connect devices in parallel or in three-phase? Yes, up to six identical devices on the same battery, with identical DC cables and direct UTP connections; three-phase only in star, not in delta. Which RCD is allowed on the output? Type A is permitted. The built-in earth relay connects neutral and earth during inverter operation. What settings do I configure for an inverter generator or weak shore power? Use PowerControl and PowerAssist with AC input current limiting and enable the dynamic current limiter for inverter generators; WeakAC is for distorted grid voltage. Can I use this device for ESS with feed-in? Yes, with a GX device. This model is listed on Victron certificates EN 50549-1 and IEC 62116. Contact Would you like to know which cable, fuse, or GX device belongs to your installation, or how to connect multiple devices? Feel free to contact us; we are happy to help you think about your system. Contact Top Systems (https://www.top.systems/nl/contact/). Specifications Battery voltage 48V DC input range 38-66V Nominal power 3000VA Continuous power 25/40/65 °C 2400W / 2200W / 1700W Peak power 5500W Charging current 35A Charging voltage absorption/trickle/storage 57.6V / 55.2V / 52.8V Automatic transfer switch 32A Maximum efficiency 95% No-load power / AES / search mode 11W / 7W / 2W AC input 187-265 VAC, 45-65 Hz Output voltage 230 VAC ±2%, 50 Hz ±0.1% AC output -2 (Mains voltage only) PowerControl / PowerAssist Yes / Yes Communication VE.Bus, 2x RJ45 Parallel / three-phase Up to 6 identical devices; Three-phase star connection Recommended DC fuse 125A Battery cable 0-5 m / 5-10 m 35mm² / 70mm² Battery connection M8 bolts, 12 Nm AC connection Screw terminals max. 13mm² Housing Steel, blue RAL 5012 Protection class IP22 Operating temperature -40 to +65 °C, fan-cooled Weight 19 kg Standards EN-IEC 60335-1, 60335-2-29, 62109-1, 62109-2 Warranty 5 years EAN 8719076058359 We would be happy to provide you with more information about this product. Please contact us contact join us.
an electric sloop? See our full range.