Victron MultiPlus-II 48/4k5/55-32 230V

Available for backorder

Original price was: €930.49.Current price is: €790.92.

Victron MultiPlus-II 48/4k5/55-32 230V – We would be happy to provide you with more information about this product. Please contact us.

PMP482405012

Available for backorder

Victron MultiPlus-II 48/4k5/55-32 230V

Victron MultiPlus-II 48/4k5/55-32 230V For energy storage and emergency power in homes, off-grid living, commercial buildings, and drives with a 48V battery bank, where 4000W continuous power is sufficient. With a GX device, the combination functions as an ESS: storing solar power, increasing self-consumption, and taking over the power supply within 20 ms in the event of a grid failure. Also known as 48/4500; expandable to three-phase. Battery voltage Suitable for 48V battery banks. The AC input accepts 187-265 VAC at 45-65 Hz; the output delivers 230 VAC ±2% ​​at 50 Hz ±0.1%, switchable to 60 Hz. Power Nominal 4500VA. Continuous 4000W at 25 °C, 3700W at 40 °C, and 3000W at 65 °C. Momentary 4500W for 2 hours and 6000W for 25 minutes. Peak power 7000W for 1 minute. Maximum efficiency 95%. No-load power 20W, 13W in AES mode, and 8W in search mode. The automatic transfer switch handles a maximum of 32A; with PowerControl and PowerAssist, the combination limits the input current and supplements any deficit from the battery. Battery charger Charging current 55A (50A at 40°C). Adaptive four-phase charger with bulk, absorption, trickle, and storage (BatterySafe). Charging voltages 57.6V absorption, 55.2V trickle, and 52.8V storage. Voltage detection compensates for voltage loss across the battery cables. Connectable Up to six identical devices in parallel on the same battery, using DC cables of equal length and cross-section and UTP cables directly from device to device. Three-phase only in star configuration, not in delta. Use one remote control per system. Operation and readout via a Digital Multi Control, the VE.Bus Smart dongle, or a GX device such as the Cerbo GX. Construction: Steel housing in blue (RAL 5012), protection class IP21, fan-cooled, operating temperature -40 to +65 °C. Protected against short circuit, overload, over- and under-battery voltage, over-temperature, 230 VAC on the inverter output, and excessive ripple voltage on the input. Installation: Victron recommends a 180A DC fuse and 50mm² battery cable for cable lengths up to 5 m, or 70mm² for 5 to 10 m; copper cable suitable for 90 °C. Connect the battery to 1x M8 plus and 1x M8 minus, using 12 Nm. Protect the AC input with a fuse or circuit breaker of maximum 32A. AC connection via screw terminals with 2 Nm. A Type A residual current device is permitted on the output. Communication via VE.Bus with two RJ45 ports; no VE.Can or BMS-Can. Configuration using VEConfigure or VictronConnect via an MK3 USB interface or the VE.Bus Smart dongle. A GX device is required for monitoring via the VRM Portal – Victron Energy (https://vrm.victronenergy.com/login) and for ESS. Furthermore, two programmable auxiliary inputs, voltage detection, and remote on/off. General AC-out-1 is continuous: in the event of a mains failure, the inverter takes over the power supply within 20 ms. AC-out-2 is a 32A auxiliary output that switches off during battery operation and switches back on after the return of mains voltage, for example for a water heater. With a GX device suitable for ESS; the unit is listed on the Victron certificate EN 50549-1 and EN 50549-10. Can be ordered directly * Red battery cable 50mm² per meter (https://shop.top.systems/default.asp?pageid=88&webgroupfilter=16&artdetail=KABRD0105000), KABRD0105000 (category Battery cables (https://shop.top.systems/installatie/kabels/accu/)) * Black battery cable 50mm² per meter (https://shop.top.systems/default.asp?pageid=88&webgroupfilter=16&artdetail=KABZW0105000), KABZW0105000 (category Battery cables (https://shop.top.systems/installatie/kabels/accu/)) * Crimp cable lug 50mm² > M8 (https://shop.top.systems/default.asp?pageid=88&webgroupfilter=16&artdetail=PSKABOG00051), PSKABOG00051 (category Crimp lugs (https://shop.top.systems/installatie/accessoires-kabels/perskabelogen/)) * Cable set 50mm² 1.5 m red and black M8-M8 (https://shop.top.systems/installatie/kabels/accu/kabelset-50mm-1-5-mtr-rood-en-zwart-m8-m8.html), KABSET010501 (category Battery cables (https://shop.top.systems/installatie/kabels/accu/)) * Mega fuse holder M8 35-300A (https://shop.top.systems/beveiligen-schakelen/zekeringhouders/mega-zekeringhouder-m8-35-300a.html), ZEKHD0000800 (category Fuse Holders (https://shop.top.systems/beveiligen- Schakelen/fusehouders/)) * Victron VE.Bus Smart dongle (https://shop.top.systems/default.asp?pageid=88&webgroupfilter=16&artdetail=ASS030537010), ASS030537010 * Victron Digital Multi Control 200/200A (https://shop.top.systems/monitoring-control/controlpanels/victron-digital-multi-control-200-200a.html), REC020005010 (category Control panels (https://shop.top.systems/monitoring-control/controlpanels/)) * Victron Digital Multi Control 200/200A GX (90º) (https://shop.top.systems/monitoring-controle/bedieningspanelen/victron-digital-multi-control-200-200a-gx-90.html), DMC000200010R (category Control panels (https://shop.top.systems/monitoring-controle/bedieningspanelen/)) * Victron Cerbo GX MK2 (https://shop.top.systems/monitoring-controle/bedieningspanelen/victron-cerbo-gx-mk2.html), BPP900451100 (category Control panels (https://shop.top.systems/monitoring-controle/bedieningspanelen/)) Related products * Victron MultiPlus-II 48/5000/70-50 230V (https://shop.top.systems/omvormen-laden/omvormen-laden-combi/victron-multiplus-ii-48-5000-70-50-230v.html), PMP482505012 * Victron MultiPlus-II 48/6k5/100-50 230V (https://shop.top.systems/omvorm-laden/omvorm-laden-combi/victron-multiplus-ii-48-6k5-100-50-230v.html), PMP482605012 * Victron MultiPlus-II 48/8000/110-100 (https://shop.top.systems/omvorm-laden/omvorm-laden-combi/victron-multiplus-ii-48-8000-110-100.html), PMP482805000 * Victron MultiPlus-II 48/10000/140-100 (https://shop.top.systems/omvorm-laden/omvorm-laden-combi/victron-multiplus-ii-48-10000-140-100.html), PMP483105000 * Victron MultiPlus-II 48/15000/200-100 (https://shop.top.systems/omvorm-laden/omvorm-laden-combi/victron-multiplus-ii-48-15000-200-100.html), PMP483150000 * Victron MultiPlus-II 48/3000/35-32 (https://shop.top.systems/omvorm-laden/omvorm-laden-combi/victron-multiplus-ii-48-3000-35-32.html), PMP482305012 Documentation * Datasheet MultiPlus-II 4k, 4k5, 6k5 and 10k (NL) (https://www.victronenergy.com/upload/documents/Datasheet-MultiPlus-II-inverter-charger-4k-4k5-6k5-10k-NL-.pdf) * Datasheet MultiPlus-II 4k, 4k5, 6k5 and 10k (EN) (https://www.victronenergy.com/upload/documents/Datasheet-MultiPlus-II-inverter-charger-4k-4k5-6k5-10k-EN.pdf) * Manual MultiPlus-II 4k, 4k5 and 6k5 230V (NL) (https://www.victronenergy.com/upload/documents/MultiPlus-II_4k_4k5_6k5_10k_230V/32424-MultiPlus-II___Quattro-II-pdf-nl.pdf) * Manual MultiPlus-II 4k, 4k5 and 6k5 230V (EN) (https://www.victronenergy.com/upload/documents/MultiPlus-II_4k_4k5_6k5_10k_230V/32424-MultiPlus-II___Quattro-II-pdf-en.pdf) * Online manual MultiPlus-II 4k, 4k5 and 6k5 230V (NL) (https://www.victronenergy.com/media/pg/MultiPlus-II_4k_4k5_6k5_10k_230V/nl/index-nl.html) * Online manual MultiPlus-II 4k, 4k5 and 6k5 230V (EN) (https://www.victronenergy.com/media/pg/MultiPlus-II_4k_4k5_6k5_10k_230V/en/index-en.html) * Online manual ESS Design and Installation (EN) (https://www.victronenergy.com/media/pg/Energy_Storage_System/en/index-en.html) * VE.Bus parallel, split and three-phase systems (EN) (https://www.victronenergy.com/live/ve.bus:manual_parallel_and_three_phase_systems) * VE.Bus error codes (EN) (https://www.victronenergy.com/live/ve.bus:ve.bus_error_codes) * EU Declaration of Conformity MultiPlus-II (https://www.victronenergy.com/upload/documents/DoC-MultiPlus-II-(EU)-0226.pdf) * EN-IEC Certificate 62109-1 and 2 all MultiPlus-II (GX) (https://www.victronenergy.com/upload/documents/Certificate-EN-IEC-62109-1-2-all-MultiPlus-II-(GX).pdf) * Certificate EN 50549-1 and EN 50549-10 MultiPlus-II (GX) 24V 3k, 48V 3k, 4k5, 5k, 6k5 (https://www.victronenergy.com/upload/documents/Certificate-ESS-EN-50549-1-EN-50549-10-MultiPlus-II-(GX)-24V-3kV-48V-3kV-4,5kV-5kV-6.5kV.pdf) * Dimensions MultiPlus-II 48V 4k5 230V (https://www.victronenergy.com/upload/documents/MultiPlus-II-48V4k5-230V.pdf) * Victron Energy ISO 9001 Certificate (https://www.victronenergy.com/upload/documents/ISO9001-certificate-2024-EN.pdf) Videos * Introduction: MultiPlus-II (EN) (https://www.youtube.com/watch?v=nU5yUY6VhIU) * Did You Know – You can update a MultiPlus Firmware using an Android Phone? (EN) (https://youtu.be/AEPmjkyg7UY) Question & Answer Why does AC-out-2 switch off when running on battery power? It is designed this way: AC-out-2 switches off during battery operation and switches back on after the return of mains power. Connect consumers to it that are allowed to switch off in the event of a power outage. Can I connect devices in parallel or in three-phase? Yes, up to six identical devices on the same battery, with identical DC cables and direct UTP connections; three-phase only in star, not delta. Which RCD is allowed on the output? Type A is permitted. The built-in earth relay connects neutral and earth in inverter operation. What settings do I configure for an inverter unit or low shore power? Use PowerControl and PowerAssist with AC input current limiting and switch on the dynamic current limiter for an inverter unit; WeakAC is for distorted mains voltage. Can I use this device for ESS with grid feed-in? Yes, with a GX device. This model is listed on the Victron certificate EN 50549-1 and EN 50549-10; you select the grid code in VEConfigure. Contact Would you like to know which cable, fuse, or GX device belongs to your installation, or how to connect multiple devices? Feel free to contact us; we are happy to help you think about your system. Contact Top Systems (https://www.top.systems/nl/contact/). Specifications Battery voltage 48V Nominal power 4500VA Continuous power 25/40/65 °C 4000W / 3700W / 3000W Immediate power 4500W for 2 hours and 6000W for 25 minutes Peak power 7000W for 1 minute Charging current 55A (50A at 40 °C) Charging voltage absorption/trickle/storage 57.6V / 55.2V / 52.8V Automatic transfer switch 32A Maximum efficiency 95% No-load power / AES / search mode 20W / 13W / 8W AC input 187-265 VAC, 45-65 Hz Output voltage 230 VAC ±2%, 50 Hz ±0.1% AC output -232A, mains voltage only PowerControl / PowerAssist Yes / Yes Communication VE.Bus, 2x RJ45 Parallel / three-phase Up to 6 identical devices; three-phase in star configuration Recommended DC fuse 180A Battery cable 0-5 m / 5-10 m 50mm² / 70mm² Battery connection 1x M8 plus and 1x M8 minus, 12 Nm Housing Steel, blue RAL 5012 Protection class IP21 Operating temperature -40 to +65 °C, fan-cooled Dimensions (hxwxd) 590 x 275 x 149 mm Weight 22 kg Warranty 5 years EAN 8719076065975 We would be happy to provide you with more information about this product. Please contact us contact join us.
an electric sloop? See our full range.