Victron Quattro 48/15000/200-100/100 277V

Available for backorder

Original price was: € 3,790.93.Current price is: € 3,222.29.

Victron Quattro 48/15000/200-100/100 277V – We would be happy to provide you with more information about this product. Please contact us.

QUA483150100

Available for backorder

Victron Quattro 48/15000/200-100/100 277V

Victron Quattro 48/15000/200-100/100 277V For installations with a 277 VAC grid, such as commercial buildings and off-grid locations outside Europe, with a large 48V battery bank. Two 100A inputs combine grid and generator, the 200A charger quickly recharges the battery bank, and in the event of a power outage, the inverter takes over the power supply. The second AC output powers a water heater only when mains voltage is available. Also known as Quattro 48/15k 277V. Battery voltage Suitable for 48V battery banks. The output supplies 277 VAC. The combination has two AC inputs, for example for shore power and a generator; AC-in-1 takes precedence if both have voltage. Power Continuous 12000W at 25 °C, 10000W at 40 °C and 7000W at 65 °C; Nominal 15000VA. Peak power 25000W. Maximum efficiency 96%. The automatic transfer switches pass 100A per input; PowerControl and PowerAssist limit the input current and supplement any deficit from the battery. Battery charger: Adaptive four-phase charger, charging current 200A. Charging voltages: 57.6V absorption, 55.2V trickle, and 52.8V storage. Connectable: Can be switched in parallel or in three-phase with identical devices via the two RJ45 VE.Bus ports. Remote control via a Digital Multi Control, the VE.Bus Smart dongle, or a GX device such as the Cerbo GX. Construction: Aluminum housing in blue (RAL 5012), protection class IP21, fan-cooled. Protected against short circuit, overload, over- and under-battery voltage, over-temperature, and excessive input ripple voltage. Installation: Victron recommends a 600A DC fuse and a battery cable of 2x 95mm² for cable lengths up to 5 m, or 2x 150mm² for lengths of 5 to 10 m. Connect the battery to M8 bolts with a maximum torque of 14 Nm. Connect the AC cables to M6 bolts with a maximum torque of 7 Nm. Protect each AC input with a maximum torque of 100A. Communication: VE.Bus with two RJ45 ports. Configuration via VEConfigure using an MK3 USB interface or via VictronConnect with the VE.Bus Smart dongle. Monitoring via the VRM Portal – Victron Energy (https://vrm.victronenergy.com/login) using a GX device. Furthermore, three programmable relays (230V/4A AC, 4A up to 35 VDC, 1A up to 60 VDC), two auxiliary inputs, and remote on/off. General AC-out-1 is continuous: in the event of a mains failure, the inverter takes over the power supply. AC-out-2 is an auxiliary 50A output that switches off immediately during battery operation and switches back on upon the return of mains voltage, for example for a water heater. Can be ordered directly * Red battery cable 95mm² per meter (https://shop.top.systems/installatie/kabels/accu/accukabel-rood-95mm-per-meter.html), KABRD0109500 (category Battery cables (https://shop.top.systems/installatie/kabels/accu/)) * Black battery cable 95mm² per meter (https://shop.top.systems/installatie/kabels/accu/accukabel-zwart-95mm-per-meter.html), KABZW0109500 (category Battery cables (https://shop.top.systems/installatie/kabels/accu/)) * Crimp cable lug 95mm² > M8 (https://shop.top.systems/installatie/accessoires-kabels/perskabelogen/perskabeloog-95mm-m8.html), PSKABOG00094 (category Crimp cable lugs (https://shop.top.systems/installation/accessories-cables/press-cable-eyes/)) * Victron VE.Bus Smart dongle (https://shop.top.systems/monitoring-control/draadloos/victron-ve-bus-smart-dongle.html), ASS030537010 * Victron interface MK3-USB (VE.Bus to USB) (https://shop.top.systems/installation/interface/victron-interface-mk3-usb-ve-bus-to-usb.html), ASS030140000-C * Victron Digital Multi Control 200/200A (https://shop.top.systems/monitoring-control/controlpanels/victron-digital-multi-control-200-200a.html), REC020005010 (category Control Panels (https://shop.top.systems/monitoring-control/controlpanels/)) * Victron Digital Multi Control 200/200A GX (90º) (https://shop.top.systems/monitoring-control/controlpanels/victron-digital-multi-control-200-200a-gx-90.html), DMC000200010R (category Control panels (https://shop.top.systems/monitoring-control/controlpanels/)) * Victron Cerbo GX MK2 (https://shop.top.systems/monitoring-control/controlpanelen/victron-cerbo-gx-mk2.html), BPP900451100 (category Control panels (https://shop.top.systems/monitoring-control/controlpanelen/)) Documentation * Datasheet Quattro 15kVA 277V (NL) (https://www.victronenergy.com/upload/documents/Datasheet-Quattro-15kVA-277V-NL.pdf) * Datasheet Quattro 15kVA 277V (EN) (https://www.victronenergy.com/upload/documents/Datasheet-Quattro-15kVA-277V-EN.pdf) * Manual Quattro 15k 277V (EN) (https://www.victronenergy.com/upload/documents/Manual-Quattro-15K-277V-EN.pdf) * Quick Install Guide Quattro 48V 10kVA 120V and 48V 15kVA 230V/277V (EN) (https://www.victronenergy.com/upload/documents/Quick-Install-Guide-Quattro-48V-10kVA-120V-48V-15kVA-230V-277V-EN.pdf) * Dimensions Quattro 48V 15000VA 230V and 277V (https://www.victronenergy.com/upload/documents/Quattro-48V-15000VA-230V-277V.pdf) * VE.Bus parallel, split and three-phase systems (EN) (https://www.victronenergy.com/live/ve.bus:manual_parallel_and_three_phase_systems) * VE.Bus error codes (EN) (https://www.victronenergy.com/live/ve.bus:ve.bus_error_codes) * ISO 9001 certificate Victron Energy (https://www.victronenergy.com/upload/documents/ISO9001-certificate-2024-EN.pdf) Videos * VEConfigure basic (EN) (https://www.youtube.com/watch?v=V1Zceq02vMA) Q&A Why does AC-out-2 fail when I am on shore power? AC-out-2 switches off immediately as soon as the combination runs on the battery and returns after the mains voltage returns. If the shore power briefly drops out, AC-out-2 will also drop out briefly. Which AC input do I use for the generator? AC-in-1 takes precedence if both inputs have voltage; you usually connect the generator to this, and the shore power to AC-in-2. Which fuse and battery cable do I use? Victron recommends 600A and 2x 95mm² for a cable length of up to 5 m, or 2x 150mm² for 5 to 10 m. Can I connect multiple devices? Yes, you connect identical devices in parallel or in three-phase via VE.Bus. Use DC cables of equal length and cross-section. Contact Would you like to know how to combine shore power and a generator on the two inputs, or which cable and fuse belong to your installation? Feel free to contact us; we are happy to help you think about your system. Contact Top Systems (https://www.top.systems/nl/contact/). Specifications Battery voltage 48V Nominal power 15000VA Continuous power 25/40/65 °C 12000W / 10000W / 7000W Peak power 25000W Maximum efficiency 96% AC inputs 2, AC-in-1 with priority Automatic transfer switch 100A per input AC-out 250A, mains voltage only PowerControl / PowerAssist Yes / Yes Charging current 200A Charging voltage absorption / trickle / storage 57.6V / 55.2V / 52.8V Output voltage 277 VAC Communication VE.Bus, 2x RJ45 Parallel / three-phase Yes, with identical devices Programmable relays 3x, 230V/4A AC, 4A up to 35 VDC, 1A up to 60 VDC Recommended DC fuse 600A Battery cable 0-5 m / 5-10 m 2x 95mm² / 2x 150mm² Battery connection M8 bolts, max. 14 Nm Housing Aluminium, blue RAL 5012 Protection class IP21 Weight 72 kg Warranty 5 years EAN 8719076062189 We would be happy to provide you with more information about this product. Please contact us contact join us.
an electric sloop? See our full range.